Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connections - Erreka VIVO-D102 Installateur-Bedienungsanleitung

Für den antrieb 'izar' mit encoder
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 77
4

ELECTRICAL CONNECTIONS

Complete the installation in line with low voltage regulations and applicable rules.
Use cables with sufficient section, always earthed.
Check the manufacturer's instructions for all the elements installed.
Power supply and operator connections
This control board has been designed and
constructed for connection to IZAR operators
with
encoder.
The
operators may result in incorrect operation,
and may produce accidents and failures. If in
doubt, check with an ERREKA agent.
IZAR Operator with encoder
F1
Main fuse (D102: 2.5A; D102M: 4A)
TRAFO
Transformer
(supplied installed and connected)
STOP
Release switch cable connectors (normally
closed), only in IZAR operators with encoder
and release
connection
of
other
D102:
D102M: 125Vac/ 60Hz
1
2
3
4
5
6
STOP
7
O
These operators do not require capacitors for
operation.
230Vac/ 50Hz
MOTOR
M
GND
SNG1
ENCODER
V+
G1
Blue (motor)
G2
Red (motor)
P14 (GND) Mesh (encoder mesh) (–)
P15 (SNG1) Green (encoder signal) (S)
P13 (V+)
Brown (encoder power supply) (+)
INSTALLATION
G1
G2
P14
P15
P13
P155Y
VIVO-D102 Control board
45

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vivo-d102m

Inhaltsverzeichnis