3.2 - Wiring for 24V outputs:
Second radio channel or photo-test output
Output for viewing gate movement
Number
Description
1-2-3
Power supply line
4-5
Output for flashing light
6-7-8
Output for powering the electric motor
Second radio channel or photo-test
9-11
output
10-11
Gate movement warning output
11-12
24Vdc output to power accessories
3.3 - Input wiring
The control panel is supplied with non-jumpered normally closed safety inputs (STOP, FOTO, STPA), add a jumper between the common (COM) and input
you do not intend to use.
3.3.1 - Connecting control buttons and key switch
Normally open contacts (the red AP/CH or APED LEDS light up when the selector or buttons connected in parallel are operated):
Terminal
Description
number
14-17-20
COM: Control inputs common (permanent GND)
FCAP: Opening limit switch Input if the gate opens to the right (P18 = R), closing limit switch input if the gate opens to
13
the left (P18 = L)
FCCH: Closing limit switch Input if the gate opens to the right (P18 = R), opening limit switch input if the gate opens to
15
the left (P18 = L)
16
OPEN: Opening-only button input, dedicated for timer or detector for magnetic induction coils
18
APCH: Sequential control input, to govern the complete travel of the gate
19
APED: Sequential control input, to govern the pedestrian travel of the gate
21
STOP: Input for stopping the gate
22
PHOTO: Photocell input, active during gate closing
23
STPA: Input for edges or internal photocell, active during gate closing and opening
-
- -
+
Function
Power line 230 V ac (1 = phase / 2 = ground wire / 3= neutral)
Output for flashing light (230 V a.c. max 40 W)
Output powering the motor (6 = common / 7 = opens / 8 = closes) the capacitor is con-
nected in terminal 7 and 8 in parallel with the electric motor
Second radio channel or photo-test output (selectable with parameter P08, max. 65 mA)
Gate movement warning output (selectable with parameter P07, max. 65 mA)
24 V dc output to power photocells and accessories (11 = GND / 12 = +24 Vdc max 300 mA)
17 18 19 20 21 22 23
EN
24Vdc output to power photocells and accessories
Fig. 6
Fig. 5
Input type
-
Normally closed
Normally closed
Normally open
Normally open
Normally open
Normally closed
Normally closed
Normally closed