BRS-FP/BRS-FPi
NOTICE
• Make sure that only clean and dry compressed air is used.
6.5.2 Set of clamping jaws
Each clamping jaw is positioned in the clamp lever using a cylinder bolt Ø 4 x 10 and is secured
using a cylinder head screw M5x16.
Each stationary locating jaw is bolted onto the clamping body using two countersunk screws M5x12.
1
2
Fig. 11
6.5.3 Mounting the reamer
1
Fig. 12
NOTICE
• When changing the reamer, only use tools with a suitable width across flats.
1 Mount the reamer (2) into the reamer holder.
2 Tighten the reamer (2) (min. 20 Nm).
BAL.0028 • 2017-03-10
The compressed air must correspond at least to the quality class 4 according to ISO 8573-1.
1
4
3
Clamping jaw
3
Stationary locating jaw
Set of clamping jaws
1
Reamer holder
2
Mounting the reamer
Reamer seat AF 27 mm, reamer AF 17 mm.
2
Cylinder bolt
4
2
3
Reamer
3
6 Commissioning
Cylinder head screw
Tool
EN - 19