Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Ec Declaration Of Conformity - Makita HP2070 Betriebsanleitung

2-gang-schlagbohrmaschine
Vorschau ausblenden Andere Handbücher für HP2070:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• A stuck bit can be removed simply by setting the
reversing switch to reverse rotation in order to back out.
However, the tool may back out abruptly if you do not
hold it firmly.
• Always secure small workpieces in a vise or similar
hold-down device.
When drilling in wood, metal or plastic materials, turn the
action mode changing lever to the position of
use "rotation only" action.

MAINTENANCE

CAUTION:
• Always be sure that the tool is switched off and
unplugged before attempting to perform inspection or
maintenance.
Indicator lamp (Fig. 13)
The green power-ON indicator lamp lights up when the
tool is switched ON. If the indicator lamp is lit but the tool
does not start, the carbon brushes may be worn out, or
the electric circuit or the motor may be defective. If the
indicator lamp does not light up and the tool does not
start, the ON/OFF switch or the mains cord may be
defective.
The red service indicator lamp lights up when the tool is
excessively loaded. Continued operation under such a
condition will result in a failure or breakage of the tool.
At this time, cool down the tool by running the tool under
no load.
Cleaning vent holes (Fig. 14 & 15)
The tool and its air vents have to be kept clean. Regularly
clean the tool's air vents or whenever the vents start to
become obstructed.
To maintain product SAFETY and RELIABILITY, repairs,
carbon brush inspection and replacement, any other
maintenance or adjustment should be performed by Mak-
ita Authorized Service Centers, always using Makita
replacement parts.
8
The typical A-weighted noise levels are
The typical weighted root mean square acceleration
m
symbol to
value is 9 m/s
EC-DECLARATION OF CONFORMITY
We declares under our sole responsibility that this prod-
uct is in compliance with the following standards of stan-
dardized documents,
in accordance with Council Directives, 73/23/EEC,
89/336/EEC and 98/37/EC.
MAKITA INTERNATIONAL EUROPE LTD.
Michigan Drive, Tongwell, Milton Keynes,
Bucks MK15 8JD, ENGLAND
Noise and Vibration
sound pressure level: 97 dB (A)
sound power level: 110 dB (A)
– Wear ear protection. –
2
.
HD400, EN50144, EN55014, EN61000
Yasuhiko Kanzaki CE2003