Herunterladen Inhalt Inhalt Diese Seite drucken

Danger Or Hazard Levels; Proper Use; Function - Kärcher HWE 4000 Oil Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Danger or hazard levels

DANGER
Immediate danger that can cause severe injury or even death.
WARNING
Possible hazardous situation that could lead to severe injury or
even death.
CAUTION
Pointer to a possibly dangerous situation, which can lead to minor
injuries.
ATTENTION
Pointer to a possibly dangerous situation, which can lead to prop-
erty damage.

Proper use

The hot water generator HWE 4000 is a ready-to-use preinstalled
once-through tankless water heater for stationary high-pressure
cleaning units with a top-fired fan burner for heating oil "EL".
Note: It is prohibited to use any other fuels!
The HWE 4000 is designed for three operating modes (also see
chapter "Function"):
– Pressure-side hot water generation for stationary nozzle sys-
tems (for e.g. internal cleaners).
– Generation of saturated steam for cleaning purposes (up-
grade kit for steam stage only).
– Pressure-side hot water generation for operating the spray jet
with reduced flow quantity (upgrade kit for spray jet operation
only).
Note: There is an important connection between temperature,
pressure and flow quantity in the 3 operating types. It is prohibited
to use components or attachments other than those listed in the
operating instructions.
This basically concerns:
– All nozzles.
– Pump module and attachments.
– Burner and attachments.
DANGER
Risk of injury! Follow the respective safety regulations when op-
erating at gas stations or other dangerous areas.
Please do not let mineral oil contaminated waste water reach
soil, water or the sewage system. Perform engine cleaning and
bottom cleaning therefore only on specified places with an oil
trap.
The plant drawing shows the appliance with a high pressure
pump module and all attachment sets connected in a series for a
specific purpose.
It is possible to operate in 3 modes through the physical relations
between pressure, flow quantity and temperature:
– Operating with hot water
– spray jet operation (with upgrade kit spray jet only)
– Steam operation (with upgrade kit for steam stage only)
Operating with hot water
(see system schematic)
When you start the appliance, the pump module (1) transports
the entire flow quantity through the pass boiler (2) to the nozzles
(22) when the half load solenoid valve (16) is closed. The burner
ignites after approx. 30 seconds (both the stages). When the
maximum temperature is reached, the thermostat "hot water"
(10) switches off the second stage and switches it on again at
minimum temperature.
Features of this operating type:
– Flow rate: maximum
– Pressure: maximum
– Temperature range: 70 °C to 95 °C
Spray jet operation (with upgrade kit spray jet only)
(see system schematic)
After starting, the pump module (1) transports a lesser quantity
(on account of smaller nozzle opening) through the pass boiler
(2) to the spray jet (23). After approx. 30 seconds, the stage 1 of
the burner is ignited. Stage 2 is blocked in this operating mode
through a signal from the switching head (9). Hence, the warming
up phase is a little longer. If there is constant use, the tempera-
ture also levels up at a constant value (physical balance).
Features of this operating type:
– Flow rate: minimum
– Pressure: maximum
– Temperature range: below 100 °C
Steam operation (with upgrade kit for steam stage
(see system schematic)
After the start, the pump (1) transports 50% of the flow rate with
the half-load solenoid valve (16) being opened; 50% flow back to
the water inlet of the pump, through the once-through boiler (2) to
the steam nozzle (24) without pressure. The burner ignites after
approx. 30 seconds (both the stages). When the maximum tem-
perature is reached, the thermostat "Dampfstufe" (11) switches
off the second stage and switches it on again at minimum tem-
perature.
The size of the steam nozzle is designed in such a way that the
steam jet lies between 1.2 MP and 2 MPa. This helps in fulfilling
2 important conditions:
– HWE 4000 is a fired pressure device of category III.
– No steam is generated in the piping system.
Features of this operating type:
– Flow rate: 50%
– Pressure: minimum
– Temperature range: 135 °C to 145 °C
2
-
EN

Function

only)
25

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis