RESISTANCE
Range
660.0Ω, 6.600kΩ
66.00kΩ, 660.0kΩ
6.600MΩ:
66.00MΩ:
Open circuit volts: -1.2 Vdc typical , (-3.5 Vdc on 660 Ω range)
Overload protection: 1000 VDC or 750 VAC rms
CAPACITANCE
Range
6.600ηF, 660ηF
66ηF, 6.600μF, 66.00μF,660.0μF
6.6 mF
Overload protection: 1000 VDC or 750 VAC rms
TEMPERATURE (ACD-3300 IND only)
Range
0.0°C to 400.0°C
-35.0°C to 0.0°C, 400°C to 1000°C
32.0°F to 750.0°F
-30.0°F to 32.0°F, 750°F to 1832°F
Sensor type: K-type thermocouple
Overload protection: 30 V Max

DIODE TEST

Test current: 0.8 mA (approximate)
Accuracy: ± (1.5% rdg + 5 dgts)
Open circuit volts: 3.2 Vdc typical
Audible indication: < 0.03 V
Overload protection: 1000 VDC or 750 VAC rms
Accuracy
± (1.0% rdg + 5 dgts)
± (2.0% rdg + 5 dgts)
± (3.5% rdg + 5 dgts)
Accuracy
±(3.0% rdg + 20 dgts)
±(3.0% rdg + 10 dgts)
±(5.0% rdg + 10 dgts)
Accuracy
± (1.0% + 1°C)
± (2.0% + 3°C)
± (1.0% + 2°F)
± (2.0% + 6°F)