Construction

1
2
3
4
5
Construction
Item
Name
1
Connector plug
2
Optical position indicator
3
Manual override
4
Valve housing
5
Valve body

10 Installation and connection

CAUTION
Damage to the valve body!
The solenoid valve may only be
G
installed in aligned pipes in order to
avoid stresses in the valve body.
10.1 Installation with solvent
cement sockets
CAUTION
Damage to the valve body!
Only use solvent cement suitable for
®
the valve body.
The solvent cement is not included
in the scope of delivery!
Apply solvent cement on the inside of
G
the valve body and on the outside of the
piping as specifi ed by the solvent cement
manufacturer.
Connect the valve body to the piping.
G
10.2 Installation with solvent
cement spigots
Damage to the valve body!
Only use solvent cement suitable for
®
the valve body.
The solvent cement is not included
in the scope of delivery!
2
1

Installation with solvent cement spigots

Apply solvent cement on the outside
G
of the valve body spigots 1 and on
the inside of the piping connector 2
as specifi ed by the solvent cement
manufacturer.
Connect the valve body to the piping.
G
10.3 Installation with
threaded sockets
The thread sealant is not included
in the scope of delivery!
Screw the threaded connections into the
G
piping in accordance with valid norms.
Use appropriate thread sealant.
G