Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Using The Appliance - HASE Modena Gas Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Modena Gas:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Spares list
Use only genuine manufacturer supplier replacement parts.
Burner Mat
Control Tap (BF)
Injector Natural (BF)
Injector LPG (BF)
Pilot Natural (BF)
Pilot LPG (BF)
Glass window
3.2

Troubleshooting

The gas pilot will not ignite or stay lit?
Ensure the gas is turned on at the appliance and the meter/cylinder.
Ensure that the pilot injector is not obstructed or
blocked and it is free from any dust or dirt.
Ensure that the thermocouple has not been damaged in transit.
This is a very delicate Electro-magnetic device.
On propane, the cylinder could be empty.
You may need to repeat the ignition sequence several times.
The pilot is not burning or performing correctly?
Ensure the pilot fl ame is the correct size for the type of gas. The
fl ame should be focused on the thermocouple probe.
The pilot fl ame will have been set correctly in the factory.
The Main Burner does not seem to be burning correctly?
Ensure adequate gas pressure to the appliance. Test pressure by releasing the
pressure test screw and applying a manometer. Ensure adequate volume of
gas is being used. Once the fi re is burning on maximum, turn off all other gas
appliances in the house and calculate the fuel being burned from the gas meter.
Make sure that the burner is burning correctly. The fl ame should be even
across the top of the burner before any coals are placed on top.
4.

Using The Appliance

It is very important to read these instructions thoroughly before lighting.
This appliance will produce an odour and/or smoke for the fi rst few hours of use when new.
Please ventilate the room when fi rst lighting from new.
There is a monitoring system fi tted to this appliance, which cuts off the gas supply upon
the detection of a blocked fl ue. If this system activates and the appliance cuts out, allow 3
minutes before retrying the ignition, noting that the control tap must fi rst be returned to the
off position. If the pilot will not light, allow a further 3 minutes or suffi cient time for switch
to reset. If cutting off persists, then a professionally qualifi ed engineer should be informed.
The control panel is located behind the front panel (Fig.31). To access it, pull at the bottom
edge of the front panel to disengage the magnetic lock.
The standard control is a basic rotary tap, which has a single control knob. As an optional extra
a remote control version is available which has two rotary control knobs. The remote control
version must be specifi ed at time of ordering
All versions of this appliance operate with a
traditional pilot light. The pilot light is located in
the centre of the burner, and is visible through
the front window. If the Flame Supervision Device
Actuating Flame (the Pilot Light) is extinguished
either by intention or not, no attempt should be
made to re-light until 3 minutes have elapsed.
Fig. 31
71

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis