6.3.13 Short diagnostics (16 byte)

With this parameter in the TR operation modes the number of diagnostic bytes can be
limited from 6+51 bytes to 6+10 bytes. Therefore the measuring system can be
operated also to Profibus masters with older issue numbers in these modes.
Selection
No
Yes

6.3.14 Limit switch lower and upper limit

Is the status switched on (see commissioning function) the measuring system can
inform the master via a bit whether the actual value is within the limits.
It is valid:
Limit switch bit = 0
Limit switch bit = 1
Input lower limit, depend on the total measuring length in increments
Lower limit
Upper limit
Default
Input upper limit, depend on the total measuring length in increments
Lower limit
Upper limit
Default

6.3.15 Rpm. multiplier [1/n rpm]

With this parameter the information of the rotation speed can be scaled in arbitrary
increments between 1/1 and 1/100 rpm.
Input
Lower limit
Upper limit
Default
Printed in the Federal Republic of Germany
10/31/2018
if lower limit < actual value < upper limit
if actual value < lower limit or actual value > upper limit
0
Programmed total measuring length in increments - 1
0
0
Programmed total measuring length in increments - 1
16 777 215
1
100
1
TR - ECE - BA - DGB - 0131 - 02
Default
X
 TR-Electronic GmbH 2016, All Rights Reserved
Page 89 of 103