Table 2: Options (cont.)
Option #
Label
2M
8 M acquisition length
1R
Rackmount
Communication Signal
2C
Analyzer
3C
P6701B with system
calibration
4C
P6703B with system
calibration
31
Buffered passive probe
32
Active probe
33
Low capacitance probe
34
Differential probe
35
Active probe
36
Passive probe
37
Active probe
2F
Advanced DSP math
TDS 500D, TDS 600C & TDS 700D Supplement
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Description
Extend standard acquisition length as follows:
TDS 520D and TDS 724D: To 2 M samples on two channels and 4 M on one channel
TDS 540D, TDS 580D, TDS 754D, TDS 784D, & TDS 794D: To 2 M samples on three or
four channels, 4 M on two channels, and 8 M samples on one channel
(Option includes a hard disk and is only available for the models listed above.)
Oscilloscope comes configured for installation in a 19 inch
wide instrument rack. For later field conversions, order kit # 016-1236-00.
Oscilloscope comes configured for communications signal triggering and mask testing.
(Option applies to TDS 500D & TDS 700D only.)
Oscilloscope comes with a P6701B and calibrated short-wavelength optical reference
receiver on channel 1. (Option applies to TDS 500D & TDS 700D only, except TDS 794D.)
Oscilloscope comes with a P6703B and calibrated long-wavelength optical reference
receiver on channel 1. (Option applies to TDS 500D & TDS 700D only, except TDS 794D.)
Add a 500 MHz P6339A 10x, buffered passive probe
(Option applies only to TDS 794D.)
Add a 4 GHz P6217 active probe
(Option applies only to TDS 794D.)
Add a 3.0 GHz (probe only) P6158 20x, 1 kW, low capacitance probe
(Option applies only to TDS 580D, TDS 680C, TDS 684C, TDS 784D, and TDS 794D.)
Add a 1 GHz (probe only) P6247 differential probe
Add a 1 GHz (probe only) P6243 active probe
(Option applies only to TDS 754D, TDS 724D, TDS 540D, and TDS 520D.)
Add a 500 MHz P6139A 10X passive probe
(Option applies only to TDS 784D, TDS 600C, and TDS 580D.)
Add a 1.5 GHz P6245 active probe
(Option applies only to TDS 794D, TDS 784D, TDS 680C, TDS 684C, and TDS 580D.)
Add advanced DSP math features such as FFT, integration, and differentiation.
(Option applies only to TDS 500D models.)