Herunterladen Inhalt Inhalt Diese Seite drucken

Special Gate Or Pillar Dimensions / Opening Up To 120 - SOMFY AXOVIA MULTIPRO Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Axovia Multipro
6.3.3. Assembly recommendations
For an opening up 150°, dimension B must be zero or negative.
If the pillar is not sufficiently wide, fit a strengthening bracket (see "3.2.
Pillar strengthening bracket").
min. 529 mm
Dimension B
Dimension A
min. 250 mm
Length L
Dimension B
Min. 320 mm
Min. 162 mm
Side room
A measurement of the force of impact a er the auto-programming pro-
cess must be taken to check compliance with the safety standards.
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
min. 20 mm
Length L
885 mm
Min. 130°
Max. 150°
885 mm
90°
6.4. Special gate or pillar dimensions / opening up
to 120°
Motor arm
short
260 mm
Medium
360 mm
long
460 mm
Gate arm
short
420 mm
Medium
620 mm
long
820 mm
6.4.1. Field of application
OPENING < 90°
Length L in mm
8
00
1000
1200
1400
400
350
300
250
200
Short motor
150
arm + short
gate arm
100
Min. C =
400 mm
50
0
120° > OPENING > 90° MIN. A = 150 MM
Length L in mm
800
1000
1200
1400
400
350
Medium motor arm
300
+ short gate arm
250
Min. C =
650 mm
200
150
100
50
0
1600
1800
2000
2200
Long motor arm + long gate arm
Min. C = 600 mm
Medium motor arm +
medium gate arm
Min. C = 500 mm
LOCK RECOMMENDED
1600
1800
2000
2200
Long motor arm + medium gate arm
Min. C = 800 mm
LOCK RECOM-
LOCK OBLIGA-
MENDED
TORY
EN
2400
2500
2400
2500
12

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis