7.2. Replacing the fuse
WARNING!
To avoid electric shock disconnect the test leads before removing the
battery or the fuse. Replace only with the same type of battery or fuse.
Service should be performed only by qualified personnel.
Caution!
For continued protection against fire or other hazard, replace only with a
fuse of the specified voltage and current ratings.
Caution!
Removing the backcover and replacement of the fuses must only be
performed by qualified personnel.
F1 0,6 A / 600 V F  5 x 20 mm
10 A / 600 V F  5 x 20 mm
F2
Follow these steps to replace the fuse:
1. Turn off the meter and disconnect the test leads.
2. Unscrew the screw at battery compartment and remove it.
3. Remove the cover by unscrewing the 4 screws and pulling off the
meter's cover.
4. Remove the PCB by unscrewing the 4 screws at each corner.
5. Install the new fuse in the fuse compartment.
6. Replace the PCB and secure it with the screws.
7. Replace the cover and secure it with the screws.
8. Replace the battery compartment and secure it with the screw.