Insert the full Maxi gas cartridge, with the gas cartridge valve and hose line installed,
into the mounting.
5.5

Replacing the oxygen tank

Close the oxygen tank valve by turning it rightward.
Screw off the oxygen pressure regulator by turning it counter-clockwise with the enclosed
key.
Remove the oxygen tank from the mounting. Replace the empty oxygen tank with a full
one.
Screw the oxygen pressure regulator clockwise onto the oxygen tank.
Make sure that the gasket in the oxygen pressure regulator is present and intact.
In so doing, make sure that the connections are free of oil and grease.
5.6

Malfunctions and maintenance

Problem
The flame turns yellow
The flame gets smaller or
lifts off the burner.
Regularly check the hoses for cuts and leaks (visual inspection).
Replace the hose package with its single-tank fuse if the single-tank fuse has triggered after a
flashback.
Hoses become porous with time. Therefore, replace the hose package as soon as small cuts
appear on the hoses.
6

Disposal

6.1

Metal parts and gas cartridges

Parts of your device can be recycled.
Approved, certified recyclers are available for this. Metals must be sorted and delivered
separately to a disposal facility.
Ask your waste authority about environmentally sound disposal of non-recyclable materials
(e.g., electronic waste).
7

Customer service

Rothenberger service facilities and the manufacturer's repair department are at your service.
Naturally, we also send replacement parts promptly. Contact your dealer or the manufacturer.
Order your accessories and replacement parts through your dealer, or through our after-sales
hotline.
Tel.: +49 6195 99 52 14
14
Cause / Solution
Either the oxygen tank valve is closed or the oxygen tank
is empty.
Open the oxygen tank valve.
Replace the empty oxygen tank with a full one.
Either the gas cartridge valve is closed, or isn't open wide
enough, or the gas cartridge is empty.
Open the gas cartridge valve by turning it (farther) left, or
replace the gas cartridge. If you can still hear liquid noises
when you shake the gas cartridge, the ambient
temperature is too low for the gas to come out in
gaseous form (below -20°C).