Safety Considerations
Read all instructions before attempting to operate this
machine and save these instructions.
Warning! When using electric machines, basic safety
precuations should always be
the risk of fire, electric shock and personal injury,
including the following:
1. Work area environment
Don´t expose the machine for rain. Don´t use
it in damp or wet locations or in presence of
flammable liquids or gases.
2. Overload
Never let the machine operate fully throttled.
Always follow the regulations pertinent to the
material you are working with ie asbestos. Don´t
use the machine for purposes that it isn´t inten-
ded for.
3. Body injuries
Never let the suction come in contact with
parts of the body. The strong suction effect can
hurt the blood-vessels in the skin. Do not repair
the electric components yourself, get somebody
qualified. Faults may cause injury. See also below
under warnings.
4. Don´t abuse cord
Never pull the machine by cord. Keep cord
TECHNICAL DATA
HxWxL
Weight
Inlet
Hose length
Collection in container
Flow, max
Neg. pressure, max
Power consumption
Fine filter polyester, area
Degree of separation
(DIN 24184/3)
Soundlevel
followed to reduce
1385 x 615 x 965 mm
40 kg
φ 50 mm
5-10 m
30 l
320 m
/h
3
21 kPa
2400 kW
1.8 m
2
99.89 %
70 dB(A)
DC 3700c - 8
from heat and sharp edges. Check the electric
cable regularly if damage.
5. Important measure
With cleaning and maintenance on the mach-
ine, the power cable should be dis-connected
from the supply.
6. Maintain the machine with care
Keep machine clean and check that the hose
is entired and that all gaskets are tight. Follow
instructions. Keep handles dry and free from
oil and grease.
7. Checking of damage
Before futher use of the machine it should
be carefully checked that the machine is un-
damaged. If there are any damaged parts these
should be repaired by of a Dustcontrol authori-
zed service center.
8. Warning
Use only accessories and replacable parts
which are available in Dustcontrol catalogue.
When using faulty parts or pirate parts (espe-
cially filter) the machine could leak out
unhealthy dust which can cause personal
injuries.
Capacity
kPa
20
DC 3700c
10
100
200
300
400
m
/h
3
Art Nr 9129