Safety Considerations
Read all instructions before attempting to operate this
machine and save these instructions.
Warning! When using electric machines, basic
safety precuations should always be followed
reduce the risk of fire, electric shock and personal
injury, including the following:
1. Work area environment
Don´t expose the machine for rain. Don´t use it
in damp or wet locations or in presence of
flammable liquids or gases.
2. Overload
Never let the machine operate fully throttled.
Always follow the regulations pertinent to the
material you are working with ie asbestos.
Don´t use the machine for purposes that it isn´t
intended for.
3. Body injuries
Never let the suction come in contact with
parts of the body. The strong suction effect
can
hurt the blood-vessels in the skin. Do not repair
the electric components yourself, get
somebody qualified. Faults may cause injury.
See also below under warnings.
TECHNICAL DATA
HxWxL
Weight
Inlet
Collection container
Hose length (∅ 50)
Flow Max
Negative Pressure, Max 28 kPa
Motor Power
Fine filter polyester
Degree of separation,
(DIN 24184/3)
Sound level*/
*/ Sound level at 1,6 m height and 1 m distance according to
DIN 45635 Section 1 (4/84) in free space and at maximum airflow.
All manuals and user guides at all-guides.com
to
2.5 kW
3 kW 60 Hz
- 1470x660x1100 mm -
85 kg
85 kg
X 50 mm
X50 mm
30 l
30 l
5-15 m
5-15 m
260 m
3
/h
320 m
3
/h
31 kPa
2.5 kW
3.0 kW
2
2
1.8 m
1.8 m
> 99.9%
> 99.9%
60 dB(A)
60 dB(A)
DC 3800i - 7
4. Don´t abuse cord
Never pull the machine by cord. Keep cord
from heat and sharp edges. Check the electric
cable regularly if damage.
5. Important measure
With cleaning and maintenance on the
machine, the power cable should be
disconnected from the supply.
6. Maintain the machine with care
Keep machine clean and check that the hose
is entired and that all gaskets are tight. Follow
instructions. Keep handles dry and free from
oil and grease.
7. Checking of damage
Before futher use of the machine it should be
carefully checked that the machine is un-
damaged. If there are any damaged parts
these should be repaired by of a Dustcontrol
authorized service center.
8. Warning
Use only accessories and replacable parts
which are available in Dustcontrol catalogue.
When using faulty parts or pirate parts
(especially filter) the machine could leak out
unhealthy dust which can cause personal
injuries.
Vacuum producer capacity
kPa
20
10
DC 3800i
2.5 kW 50 Hz
100
200
DC 3800i 3.0 kW
60 Hz
300
400
m
3
/h
Art Nr 9442