Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Considerations; Technical Data - Dustcontrol DC 2800c Autostart Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Safety Considerations

Read all instructions before attempting to operate
this machine and save these instructions.
Warning! When using electric machines, basic
safety precuations should always be
reduce the risk of fi re, electric shock and personal
injury, including the following:
1. Work area environment
Don´t expose the machine for rain. Don´t use
it in damp or wet locations or in presence of
fl ammable liquids or gases.
2. Overload
Never let the machine operate fully throttled.
Always follow the regulations pertinent to the
material you are working with ie asbestos.
Don´t use the machine for purposes that it isn´t
intended for.
3. Body injuries
Never let the suction come in contact with
parts of the body. The strong suction effect can
hurt the blood-vessels in the skin. Don´t repair
the electric components yourself, get some-
body qualifi ed. Faults may cause injury. See
also below under warnings.

TECHNICAL DATA

HxWxL
Weight
Inlet
Hose length
Collecting sack, 11 l
Flow, max
Neg. pressure, max
115/230 V
Power consumption
115/230 V
Fine fi lter polyester, area
Degree of separation
(EN 60335-2-69, Class M)
Filter area, microfi lter H13
Degree of separation,
microfi lter
(EN 1822-1)
(EN 60335-2-69, Class H)
Sound level
followed to
1070x420x510 mm
14 kg
X 50 mm
5 m
500x550 mm
3
190 m
/h
21/24 kPa
1200/1400 W
1.5 m
2
99.9 %
2
0.85 m
HEPA H13
99.995 %
< 68 dB(A)
DC 2800c Autostart, 8
4. Don´t abuse cord
Never pull the machine by cord. Keep cord
from heat and sharp edges. Check the electric
cable regularly if damage.
5. Important measure
With cleaning and maintenance on the mach-
ine, the power cable should be dis-connected
from the supply.
6. Maintain the machine with care
Keep machine clean and check that the hose
is entired and that all gaskets are tight. Follow
instructions. Keep handles dry and free from
oil and grease.
7. Checking of damage
Before futher use of the machine it should be
carefully checked that the machine is unda-
maged. If there are any damaged parts these
should be repaired by of a Dustcontrol authori-
zed service center.
8. Warning
Use only accessories and replacable parts
which are available in Dustcontrol catalogue.
Vacuum producer
capacity
kPa
20
15
10
1200 W
5
0
50 100 150 200 m
1400 W
3
/h
Part No 94116

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis