Herunterladen Inhalt Inhalt Diese Seite drucken

Calling Up The Camera Via A Computer; Specifications - Monacor INC-2036DF Anleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INC-2036 DF
Order Number 18.4690
ELECTRONICS FOR SPECIALISTS
ELECTRONICS FOR SPECIALISTS
2) To stop the search, click the button "Stop".
3) Select the camera from the list. The current settings of this camera can be
found on the right.
4) Change the settings as required:
IP address, subnet mask and gateway address can be defined as static values
(select the option "Device uses the following IP address"). Enter a unique IP
address for each camera. If a DHCP server is available in the network (e. g. in
the router or network video recorder), this server will be able to automatically
make settings for the camera (select the option "Device obtains an IP address
automatically"). The values assigned automatically are highlighted in grey and
cannot be changed.
5) Click the button "Modify". After successful transmission of the modifications,
the message "Modify success!" will appear.
6) Before you start a new search, click the button "Clear All" to delete the list.

6 Calling up the Camera via a Computer

To call up the user interface of the camera, enter its IP address in the address
bar of the program Windows Internet Explorer (IE, version 6 or higher). The IP
addresses of the computer and of the camera must be in the same subnet. The
number of simultaneous accesses to the camera is limited to 6.
When the camera is called up, the log-in window will appear. Select the lan-
guage for the user interface. The description below refers to English. Then enter
the user name and the password (default setting for both: admin). Individual
log-in data can be defined later in the camera settings.
Important: To prevent unauthorized access, change at least the password.
The Flash Player extension from Adobe provided on many computers (also avail-
able on the CD provided) will allow a basic display of the camera image. Faster
image transmission and availability of all functions, however, requires installation
of the ActiveX extensions. These extensions will be loaded from the camera when
g
the Flash/ActiveX line
(
 fig. 3) is clicked for the first time. If necessary, re-
duce the security settings of the IE accordingly to allow the installation process.
Save the installation file "webPlugins.exe" to the computer, close the IE and
execute the file.
When the connection to the camera has been established, the view with the cur-
rent camera image (fig. 3) will be displayed. The following options are available:
a
View "Live Video" with display of camera image
b
View "Playback" (without function for this camera model)
c
View "Configuration" to change the camera settings
d
Button
to change the password
e
Button
to log out
f
Camera image with information on the stream currently transmitted
g
Click this line to switch between use of Flash Player and ActiveX for display of
the live image
h
Toolbar with the following functions:
  / : Stop / Start of image transmission
"Stream": Selection of a stream (when selecting a different stream, click  to
stop the transmission of the current stream)
: Activation / Deactivation of audio transmission from the camera
[microphone (5)]
: Activation/Deactivation of audio transmission to the camera
[Audio Output (11)]
: Specific camera settings (e. g. brightness control, mirror image)
: Snapshot function to save a snapshot as an image file
When the camera image is clicked with the right mouse button, the following
menu will appear:
Menu Item
full-screen image (exit)
Full Screen (Exit Full Screen)
alternatively: double-click the image
Sensor
like
zooming in / zooming out
Zoom In / Out
alternatively: use the scroll wheel to zoom in / out or drag the
mouse to select the desired image section
Restore Panorama
display of the entire image (after zooming in)
ELECTRONICS FOR SPECIALISTS
Function
MONACOR INTERNATIONAL GmbH & Co. KG • Zum Falsch 36 • 28307 Bremen • Germany
Copyright
by MONACOR INTERNATIONAL. All rights reserved.
©
ELECTRONICS FOR SPECIALISTS
ELECTRONICS FOR SPECIALISTS
To change the settings for the camera, select the tab
"Configuration" (
  fig. 4). On the left (
the settings. To show additional subcategories, click ⊞ . To set, for example, the
current time for the camera, go to "Device  Date and Time".
To save a setting that has been changed, click the green check mark ✔ or the
button "Apply". To load the current settings from the camera, click the button
"Refresh".
Windows is a registered trademark of Microsoft Corporation in the USA and other countries.

7 Specifications

Image sensor: . . . . . . . . . . .CMOS, 8.5 mm (1⁄3 ")
Lens: . . . . . . . . . . . . . . . . . .1 : 1.2 /3.6 mm
Viewing angle: . . . . . . . . . .75°
Minimum illumination: . . . .0.01 lx (colour)
Resolution: . . . . . . . . . . . . .30 frames max. per second with
Electronic shutter: . . . . . . . .1⁄5 – 1/20 000 s
Protocols: . . . . . . . . . . . . . .IPv4, IPv6, HTTPS, RTSP, DDNS, SMTP, SSL,
Compression: . . . . . . . . . . .MPEG-4 H.264, MJPEG
Video streaming: . . . . . . . . .Mainstream 500 – 12 000 kbit /s
Audio bit rate: . . . . . . . . . .64 kbit / s
Network: . . . . . . . . . . . . . .Ethernet 10/100 Mbit/s
Ambient temperature: . . . .−10 °C to +50 °C
IP rating: . . . . . . . . . . . . . . .IP 66
Power supply: . . . . . . . . . . . ⎓ 12 V/ 350 mA or PoE IEEE 802.3af
Dimensions: . . . . . . . . . . . .⌀ 116 mm × 91 mm
Weight: . . . . . . . . . . . . . . .410 g
  a
  f
  g
  h
i
ELECTRONICS FOR SPECIALISTS
c
and go to the view
i
), select the desired category for
1920 × 1080 pixels
ONVIF 2.4 etc.
Substream
100 – 6000 kbit /s