Installation - GEMÜ 0326
The GEMÜ 0326 pilot solenoid
valve is designed for mounting
as compact valve battery on an
aluminium distributor rail.
On the back of the aluminium
distributor rail there is an M4
connection for the connection of
the potential equalisation acc. to
ATEX.
10
5
11
11
3
9
4
6
O-rings
Installation - GEMÜ 0326
1.
Remove knurled nut 10.
2.
Pull solenoid from valve body.
3.
Screw the valve body of the pilot
solenoid valve onto the aluminium
distributor rail 6 with O-rings and two
screws 11.
Important: The holes 8 in the
aluminium distributor rail must
correspond to the holes in the
valve body.
4.
Push the solenoid again on the valve
body.
5.
Tighten with knurled nut 10 (max.
0.5 Nm).
M4
connection
7
6.
Connect and seal the pressure inlet
tubing to connection "P" 2 (G 1/4).
7.
If applicable, connect and seal the
exhaust tubing to connection "R" 5 (M5)
or mount a silencer.
8.
Connect and seal the outlet tubing to
connection 4 (G 1/4).
9.
Close connections not used with
blanking plates 7.
10. Close the open connection opposite
"P" 2 with supplied sealing plug 3 and
gasket 9.
11. All threads must be sealed gas tight.
After the installation:
Reactivate all safety and protective
G
devices.
11.2 Electrical connection
8
Danger from electric shock!
2
®
G
G
Power supply varies dependent on the
G
design (see product label).
Do not bridge terminals!
G
Required for electrical
connection:
Crosshead screwdriver
Small fl at screw driver
24/32
Important: The holes 8 in the
aluminium distributor rail must
correspond to the holes in the
blanking plate.
DANGER
There is a danger of injury or
death (if operating voltage
is higher than safe extra low
voltage)!
Electrical connection only to
be carried out by an electrical
expert.
Disconnect the cable from the
power supply before making
the electrical connection.
CAUTION
0322, 0324, 0326