Electrical Connection
•
For wiring diagrams see last page.
•
VZ-, VZC- and F-fans: noise immunity accor-
ding to EN 55014-2 depending on pulse shape
and energy quota 1000 - 4000 V. These values
may be exceeded when run with fluorescent
tubes. In this case additional interference
suppression will be necessary (L-, C- or RC-
elements, protective diodes, varistors).
ECA boards [2] – Settings
Standard version
With standard PCB [2.1], speed controllable.
Permissible tolerances for time
indicated: nominal value + 20 %.
VZ version with electronic timer
With VZ 6 board [2.2] and protective cover, not
speed controllable. Permanently set fan start delay
of 50 seconds and run-on time of 6 minutes.
VZC version with variable electronic timer
With VZ 24 C board [2.3] and protective cover, not
speed controllable.
Fan start delay: Adjustable from 0-150 seconds
using setting screw Tv.
Run-on time: Adjustable from 1.5 to 24 minutes
using setting screw Tn.
F version with light control
With VZ 6 F board [2.4] and protective cover, not
speed controllable. Start-up brightness min. 30 Lux,
cut-out brightness (at the unit) max. 0.3 Lux.
Permanently set fan start delay of 50 seconds and
run-on time of 6 minutes.
The fan is designed for installation in dark rooms
without windows. It is not suited for second room
ventilation. The fan will only switch off if the room
is dark.
Spare parts
Instructions for ordering of spare parts: State the
print number 0185.0949.0003, the production date
„X" (stamp in terminal area) and the relevant part
number.
1
Housing with motor
2
ECA board
2.1 Standard PCB
2.2 VZ 6 board
2.3 VZ 24 C board
2.4 VZ 6 F board
3
Board protection cover
4
Motor
5
Impeller with annular spring
6
Motor cover
7
Motor cover fixing screw
8
Plug
9
Rating plate
10
Cover with fixed lamellas
Technical Data
See the rating plate on the motor cover or the
currently valid catalogue.
– Subject to change! –