2.4 Information displayed during operation
LED
en
Laser beam
3 Accessories
Designation
Tripod
Target plate
Target plate
Laser receiver
Magnetic holder
Telescopic brace
Frame clamp
Universal adapter
Hilti toolbox
Laser visibility glasses
4 Technical data
Right of technical changes reserved.
Range of the lines and intersection point
Accuracy
1
Self-leveling time
1 Influences such as, in particular, high temperatures, moisture, shock, fall, etc. may lead to deviations from the level of accuracy
which was set. Unless stated otherwise, the tool was adjusted or calibrated under standard ambient conditions (MIL-STD-810F).
12
The LED doesn't light.
The LED doesn't light.
The LED doesn't light.
The LED lights constantly.
The LED blinks twice every
10 seconds.
The LED blinks.
The laser beam blinks twice
every 10 seconds.
The laser beam blinks rapidly.
The laser beam blinks every 2
seconds.
Short designation
PMA 20
PMA 54/55
PRA 50/51
PMA 31
PMA 74
PUA 10
PMA 25
PMA 78
PMA 62
PUA 60
10 m (30 ft)
±2 mm at 10 m (±0.08 in at 33 ft)
3 s (typical)
The tool is switched off.
The batteries are exhausted.
The batteries are inserted incorrectly.
The laser beam is switched on. The tool
is in operation.
The batteries are almost exhausted.
The temperature of the tool is above
50°C (122°F) or below -10°C (14°F) (the
laser beam does not light).
The batteries are almost exhausted.
The tool is unable to level itself (outside
the 5° self-leveling range).
The tool is unable to level itself auto-
matically (or is set to "Inclined plane"
operating mode).
Description
The laser visibility glasses are not
protective glasses and thus do not
protect the eyes from laser beams.
As the laser visibility glasses restrict
color vision, they should be worn only
when working with the PML laser tool.
Do not wear the laser visibility glasses
while driving a vehicle on a public
road.