Permissible duct lengths

1. Interior installation with wall cowl
(refer to installation variant 1, page 2):
– Duct lengths of up to max. 70 cm can be routed as
ascending duct in any way required, or descending by
max. 30 cm.
– Duct lengths from 70 cm to max. 150 cm must be
routed as ascending duct with an ascending angle of
min. 45°.
2. Under-floor assembly with wall cowl
(refer to installation variant 4, page 2):
– Cowl double duct length max. 70 cm, routed as
ascending duct in any way required or descending by up
to 30 cm.
Interior installation using the wall
cowl kit
Refer to installation variant, Fig 1 (page 2).
Assembly of wall cowl
Assemble wall cowl on a surface which is as flat as possible
and which is exposed to wind from all directions. Drill an
opening (8) measuring 70 mm in diameter (pack wood into
hollow spaces in the area of the cowl opening). Use the pro-
vided rubber seal (10) for sealing. In the event of structured
surfaces, coat with plastic body sealant – do not use silicone.
In the event of a greater wall thickness, first connect the
exhaust double duct to the cowl from the outside.
Slide rubber seal (10) and clamp (4) onto the cowl inner
part (11).
Press end of ex-haust duct (1) together so that winding
touches winding, slide over the O-ring (2a) on the connection
fitting (2) up to the collar (3 – cowl bend pointing upward) and
tighten clamp (4) in such a way that the knurled edge of the
clamp encloses the collar.
1 4
Coat serrated connection fitting (9) with plastic body seal-
ant – do not use silicone! – and slide over combustion air sup-
ply duct (5).
Fasten cowl inner part (11) with 3 screws (12 – observe instal-
lation position! The Truma lettering must be at the bottom).
Mount cowl outer part (13) and screw on with 2 screws (14).
Always install a new O-ring following any disassembly!
18
2
2a
3
Fastening the appliance
Depending on the installation position, bolt on the appliance
using fastening strap (a) or mounting brackets (b).
Fasten exhaust double duct to the wall using duct clamp
ZR 24 (c), if necessary (parts to be found in enclosed kit).
Double cowl duct connection to the
heating appliance
Press end of ex haust duct (1) together so that winding touch-
es winding. Slide clamp (4) over exhaust duct (1). Slide ex-
haust duct over O-ring on the connection fitting (2) up to the
collar (3). Attach with clamp (4) in such a way that the knurled
edge of the clamp encloses the collar. Fasten combustion air
supply duct (5) on the connection fitting (6) using clamp (7).
Always install a new O-ring following any dis-assembly!
Under-floor assembly with wall cowl kit
Refer to installation variant fig. 4 (page 2).
Install wall cowl on as flat a surface as possible on an outside
wall (vehicle apron, refer to "Interior installation using the wall
cowl kit").
If the wall cowl is installed using mounting brackets, or
such, under the floor, the vehicle floor must be sealed
tight (refer to "Interior installation with floor cowl")!
Fastening the appliance
Screw the 3 fastening strips (1, 2 + 3) to the appliance. Screw
appliance to vehicle floor with the strips 1 + 2. Fasten assem-
bly bracket (4 – Accessories part. no. 39050-74000) together
with strip (3) and screws (5). Place lock washers under all
screw heads and nuts.