Malfunction checklist

Fault
The unit will not start
Unit will not suck
Unit sucks, but does
not produce any
pressure
Coating material
comes out of the
openings for filling
lubricant
Bad spraying results
Possible cause
Mains supply fuses have a too low value
No mains voltage
Pressure regulator set too far to the left
Carbon brushes in motor worn out
Motor safety switch 0 – 1 defect
Motor defect
Inlet valve doesn't close
Intake hose filter blocked
Lower packing worn
Coating material too thick
Pressure regulator set too far to the left
High-pressure filter blocked
Chosen tip too large
Inlet valve worn
Upper packing leaks
Pistons worn
Tip too large
Wrong pressure settings
Not enough coating material being delivered
GB
Remedy
Replace with 16 A slow-blow fuses
Check
Turn pressure regulator to the right
Replace
Have replaced by an electrician
Call Wagner-customer service
Clean or replace inlet valve
Clean or replace filter
Replace packing
Dilute
Turn pressure regulator to the right
Clean
Use smaller tip
Clean or replace
Replace packings
Change
Use smaller tip
Correct pressure setting
Clean high-pressure filter and spray gun
plug-in filter