SPECIFICATIONS

Voltage-Single Phase
Rated current
MAX Motor RPM
Cut-in Pressure
Cut-out Pressure
SCFM @ 100 PSIG (L/min @ 6.9 bar)*
SCFM @ 330 PSIG (L/min @ 23 bar)*
Bore x Stroke x Qty
Dimensions (L x H x W)
Protective earthing
Protective structure
Working temperature
Working humidity
Height above sea level
Storage temperature
Storage humidity
Outlet Max Pressure "HP"
(Exclusively for High Pneumatic Use)
Outlet Max Pressure "RP"
(Exclusively for Regular Pneumatic Use)
Sound Pressure Level (L
Sound Power Level (L
Uncertainty K
*Note:
• In consequence of operating conditions, environments and the hours of operation, outlet pressure is changed.
• Due to our continuing programme of research and development, the specifications herein are subject to change without
notice.
• Specifications may differ from country to country.
GLOSSARY
CUT-IN PRESSURE:
While the motor is off, air tank pressure drops as you
continue to use your accessory or air tool. When the tank
pressure drops to certain level the motor will restart
automatically. This is called "cut-in pressure".
CUT-OUT PRESSURE:
When you turn on your air compressor, it begins to run, air
pressure in the tank begins to build. It builds to a certain
pressure before the motor automatically shuts off -
protecting your air tank from pressure higher than its
design rating. The pressure at which the motor shuts off is
called "cut-out pressure".
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure
of air delivery.
Model
Hz
Motor Power
Tank Size
Weight
Lubrication
Noise
)
pa
)
wa
AC320H
220 - 240 V AC
50 Hz ± 1 Hz
2,500 min
2.7 - 3.1 MPa (27 - 31 bar)
3.5 MPa (35 bar)
4.4 (124 L)
3.6 (102 L)
62 mm x 26 mm x 1
41 mm x 10 mm x 1
5.5 L x 2
558 x 350 x 358 mm
Oil-Less
0°C to +40°C
85% RH or less. No dew condensation.
Up to 2,000 m
-10°C to +50°C
85% RH or less. No dew condensation.
2.45 MPa (24.5 bar)
0.88 MPa (8.8 bar)
65.2 dB (A)
85.2 dB (A)
0.85 dB (A)
PSIG: Pounds per square inch gauge; a unit of measure
of pressure.
IMPORTANT
Read the Safety Guidelines and ALL instructions carefully
before operating.
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
........... Read instruction manual.
........... Risk of electric shock
Caution: before doing any work on the
7 A
2 HP
-1
18 kg
Class I
IP 20
3