Installation

None of the connection cables must be bent nor squeezed. This can
result in malfunctions, short circuits and defects in the device.
Make sure that cables or power lines are not damaged when drilling
holes in the wall or bolting into place.
Please note, you should choose a position for your camera that is not
exposed to direct sunlight (this can cause glare). Further, the camera
must be protected from dust and vibration.
The integrated infrared LEDs allow night vision. Please note that with
increasing darkness and the associated activation of the IR LEDs, the
coloured image reproduction changes into black and white mono-
chrome. The brightness is detected by the camera using a photo
sensor on the front.
• Find a suitable location for mounting the camera.
Ensure that the plug and socket of the camera's connection cable are
not exposed to damp. These plugs and sockets may only be used in
dry areas. These plug-inconnectors must therefore (for installation in
outdoor areas or in damp areas) be installed, so that they are led into
a dry room.
• There are 3 mounting holes on the mounting base. Hold the mounting base on the
desired mounting location and mark the installationdrilling.
• Drill the mounting holes.
• Fasten the mounting base, into place using appropriate installation material.
• Screw the camera on the mounting base and tighten the ribbed locking screw.
• Adjust the camera to the desired position. To do this, loosen the locking screw and
after successfully adjusting the camera, tighten it again to secure the position.
Do not point the camera directly toward a source of bright sunlight or
toward strong or indirect illumination as this may lead to over-
exposure and a fuzzy picture.
Connection
To provide a suitable voltage supply, an optionally available power
transformer is required (12 V/DC, 300 mA, plug polarity inside=plus,
outside=minus). When acquiring this power transformer, check that
the polarity of the low-voltage plug of the power transformer corres-
ponds to the polarity marked on the low-voltage connector of the
camera.
The wrong polarity can cause damage to the camera!
Proceed as follows to make the correct connections:
• Connect the BNC connector of the camera (yellow) to the analogue video input of
your display device (e.g. monitor).
• Connect the low voltage plug of your power transformer (not included in the delivery)
to the low voltage connector (black) on the camera.
• Plug the power transformer into a domestic mains socket (230 V/AC 50 Hz).
• Turn your display device on and set the appropriate channel to enable the display
function.

Maintenance and cleaning

Before cleaning the outside of the surveillance camera's casing, unplug it from the
mains.
To clean the outside of the camera, it is sufficient to use a dry, soft and clean cloth. In
case of strong soiling, you can use a damp cloth.
Clean the lens very carefully, otherwise you may scratch it. Do not use any aggressive
cleaning agents.
Disposal
Electrical and electronic products do not belong in the household
waste!
Please dispose of the device, when it is no longer of use, according to
the current statutory requirements.

Technical Data

Image sensor:
Operating voltage:
Current consumption:
Recommended power supply:
TV lines horizontal:
Detection area, horizontal:
Detection area, vertical:
Camera lens:
Light sensitivity:
IR LEDs:
IR LED range:
Protection class:
Operating temperature:
Dimensions (D x Ø):
Weight:
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240
Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or
the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2009 by Conrad Electronic SE.
8.5 mm (1/3") Sony CCD
12 V/DC
max. 280 mA (when the IR LEDs are activated)
12 V/DC, 300 mA
Plug polarity (inside=plus, outside=minus)
420
70°
50°
6 mm
0 LUX
24
up to 20 metres
IP 65
-10°C to +50°C
approx. 85 x 52mm
approx. 310 grams (excl. mounting base)