• There are 3 mounting holes in the mounting base. Hold the mounting base against the desired
mounting spot and mark the mounting holes.
• Drill the holes.
• Fasten the mounting base into place using appropriate installation material.
• Screw the camera onto the mounting base and fasten the locking screws.
• Adjust the camera to the desired position. To do this, loosen the locking screws and after suc-
cessfully adjusting the camera, tighten them again to secure the position.
Do not point the camera directly toward a source of bright sunlight or towards
strong or indirect illumination as this may lead to overexposure and a fuzzy
picture.
Connection
To provide the suitable voltage supply, an optional power transformer is
required (recommended: 12 V/DC, 500 mA, plug polarity: inside=plus, out-
side=minus). When acquiring this power transformer, check that the polarity
of the low-voltage plug of the power transformer corresponds to the polarity
marked on the low-voltage connector of the camera.
The wrong polarity can cause damage to the camera!
Proceed as follows to make the correct connections:
• Connect the BNC connector of the camera to the video input of your display device (e.g. mon-
itor).
• Connect the low voltage plug of your power transformer (not included in the delivery) to the low
voltage connector on the camera.
• Plug the power transformer into a domestic mains socket (230 V/AC 50 Hz).
• Turn your display device on and set the appropriate channel to enable the display function.
Maintenance and Cleaning
Before cleaning the outside of the surveillance camera's casing, unplug it from the mains.
To clean the outside of the camera, it is sufficient to use a dry, soft, clean cloth. In case of marked
pollution the cloth can be moistened slightly.
Clean the lens very carefully, otherwise you may scratch it. Do not use any aggressive cleaning
agents.
Disposal
Electrical and electronic products do not belong in the household waste!
Please dispose of the device, when it is no longer of use, according to the cur-
rent statutory requirements.
Technical Data
Image sensor:
Operating voltage:
Current consumption:
Recommended power transformer:
TV lines horizontal:
Detection area, horizontal:
Detection area, vertical:
Detection angle IR-LEDs:
Camera lens:
Light sensitivity:
IR-LEDs:
IR LED range:
Protection type:
Operating temperature:
Dimensions (Ø x D):
Weight:
8.5 mm (1/3") CCD
12 V/DC
max. 300 mA (with activated IR LEDs)
12 V/DC, 500 mA
Plug polarity (inside=plus,
outside=minus)
420
45°
33°
45°
6 mm
0,001 LUX
30
up to 30 metres
IP 65
-20°C to +50°C
approx. 118 x 60 mm (without
rain shield)
approx. 275 gram (without rain cover, without
rain shield)
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240
Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or
the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2009 by Conrad Electronic SE.