Herunterladen Inhalt Inhalt Diese Seite drucken

Transport; Maintenance And Service; Maintenance And Cleaning - Bosch PCM 8 S Originalbetriebsanleitung

Gehrungssägen
Vorschau ausblenden Andere Handbücher für PCM 8 S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
In case the angle indicator 51 is not in a line with
the 45° mark of the scale 61, firstly check the 0°
setting for the bevel angle and the angle indica-
tor again. Then repeat the adjustment of the 45°
bevel angle.
Aligning the Fence
– Bring the machine into the transport posi-
tion.
– Turn the saw table 17 until it engages at 0°.
Checking: (see figure W1)
– Set an angle gauge to 90° and place it on the
saw table 17 between the fence 10 and the
saw blade 8.
The leg of the angle gauge must be flush with
the fence over the complete length.
Adjusting: (see figure W2)
– Loosen all Allen screws 32 with the Allen key
provided.
– Turn the fence 10 until the angle gauge is
flush over the complete length.
– Retighten the screws again.
Aligning the Angle Indicator (Horizontally)
(see figure X)
– Bring the machine into the transport posi-
tion.
– Turn the saw table 17 until it engages at 0°.
Checking:
The centre line of the angle indicator 14 must be
in line with the 0° mark of the scale 15.
Adjusting:
– Loosen the screw 63 using a commercial
Phillips screwdriver and align the centre line
of the angle indicator alongside the 0° mark.
– Retighten the screw again.

Transport

(see figure Y)
– Bring the machine into the transport posi-
tion.
– Remove the extension bars.
– Carry the machine by the transport handle 26
or hold it by the recessed grips 64 on the
sides of the saw table.
Bosch Power Tools
The power tool should always be carried by
two persons in order to avoid back injuries.
When transporting the power tool, use only
the transport devices and never use the
protective devices.

Maintenance and Service

Maintenance and Cleaning

Before any work on the machine itself, pull
the mains plug.
If the machine should fail despite the care taken
in manufacturing and testing procedures, repair
should be carried out by an after-sales service
centre for Bosch power tools.
In all correspondence and spare parts order,
please always include the 10-digit article
number given on the type plate of the machine.
WARNING! Important instructions for con-
necting a new 3-pin plug to the 2-wire cable.
The wires in the cable are coloured according to
the following code:
Do not connect the blue or brown wire to the
earth terminal of the plug.
Important: If for any reason the moulded plug is
removed from the cable of this power tool, it
must be disposed of safely.
Cleaning
For safe and proper working, always keep the
power tool and its ventilation slots clean.
The retracting blade guard must always be able
to move freely and retract automatically. There-
fore, always keep the area around the retracting
blade guard clean.
Remove dust and chips after each working pro-
cedure by blowing out with compressed air or
with a brush.
Clean the roller 9 and the lighting and laser unit
(24, 23) regularly.
English | 49
1 609 929 J50 | (27/11/07)

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pcm 10

Inhaltsverzeichnis