lights when the thermostat interrupts the welding
machine operation.
D-Setting knob.
adjusting this knob changes the welding wire speed.
E- Selector switch.
turns the machine on or off and selects the welding
voltage ranges.
f- Selector switch.
Fine-tunes the welding voltage within the range previously
selected via selector switch E.
g- Earth sockets.
sockets to which to connect the earth cable. (some
versions have a single earth socket ).
h- Central adapter.
this is where the welding torch is to be connected.
4.2 EVO SyNERgIC (Fig. 4).
B
c
d
e
a
F
h
i
l
m
A- Selection key.
Pressing this key causes the leds B, C, D
and E to light in sequence.
From within the sub-menu activated by the
2 keys Q and R, select the soft start, Pull 2003 motor
speed variation, and post gas functions.
B- green LED (PROgRAM).
signals that the display S shows the program
number being used.
PROGRAM
check the instructions posted inside the
mobile side panel for the diameter, wire type and gas
corresponding to the program number displayed.
12
Fig. 4
The figure on the display S is always preceded by the
letter P.
C- green LED.
signals that the display S shows the spot
welding or working time. the length of this
time is adjustable from 0.3 to 5 seconds.
setting the time to 0 disables the function. the function is
active only while welding. the value shown on the display
S is always preceded by the letter t.
D- green LED.
signals that the display S shows the pause
time between welding segments. the length
of this time is adjustable from 0.3 to 5
seconds. setting the time to 0 disables the function. the
function is active only if the welding time is not 0 and while
welding. the value shown on the display S is always
preceded by the letter t.
E- green LED (Burn-Back).
signals that the display S shows the time for
which the wire exits the welding torch, after
the operator has released the torch trigger.
s
this time ranges from 10 to 400 milliseconds. the value
q
shown on the display S is always preceded by the letter t.
r
f- yellow LED.
lights when the thermostat interrupts the
P
welding machine operation.
g
g- green LED (PULSAR).
lights and shuts off intermittently when the
PULSAR
connector of the Pull 2003 torch or sPool-
gun is connected to the connector I.
h- Central adapter.
n
this is where the welding torch is to be connected.
I- 10-pin connector.
o
this connector must be connected to the 10-pin patch
connector of the Pull 2003 torch or sPool- gun.L-M
Earth sockets.
sockets to which to connect the earth cable. (some
versions have a single earth socket ).
N- Selector switch.
turns the machine on or off and selects the welding
voltage ranges.
O- Selector switch.
Fine-tunes the welding voltage within the range selected
with the selector switch N.
P- Setting knob.
adjusts the wire speed, and is active only when using the
standard welding torch and not the Pull 2003 torch or
sPool- gun.
when using the program 00, adjusts the welding wire
speed from 0 to 20 meters/minute.
when using any synergic program, the knob indicator
must be set to the label sYnergic. choose a synergic
program; the display S indicates the current set by the