Connection
Description
OUT: Alarm
The alarm output is switched either
output
by the integrated motion detector or
by the alarm input.
The alarm output is a transistor
output (open collector) with a
maximum load of 200 mA switching
current. The output is designed
purely as a switching output. An
external power supply is required
when it is used.
G: Ground
Earth connection
IN: Alarm input
The digital input is activated by
connecting the IN and G
connections.
D/N
Connection for a light-dependent
resistor (LDR) to control the
day/night function.
Maximum load
200 mA