12 Technical Data

Operating pressure
Operating/water temperature
Ambient tempera-
operation
ture during
storage/transport
Flow rate with 1 bar pressure loss
Nominal fl ow according to Norm
Pressure loss at nominal fl ow
Empty fi lter cartridge volume
Weight (dry/wet)
Comparable capacity according to DIN 18879-1:2007
The comparable capacity is a standardised indicator to facilitate comparison of different fi lters. The comparable capacity is
determined under extreme conditions. The usable capacity in practical operation is higher than the comparable capacity and may
vary greatly depending on the usage conditions.
Comparable capacity PURITY Quell ST
Dimensions complete system
(Width/Depth/Height)
If BRITA hose sets are used, their bending radii of approx. 130 mm must be added.
Operating position
Inlet connection
Outlet connection
* with ACS Technology
Comparable capacity according to DIN 18879-1:2007
The comparable capacity is a standardised indicator to facilitate comparison of different fi lters. The
comparable capacity is determined under extreme conditions. The usable capacity in practical opera-
tion is higher than the comparable capacity and may vary greatly depending on the usage conditions.
PURITY 450 Quell ST
PURITY 600 Quell ST
PURITY 1200 Quell ST
System Tested and Certifi ed by
NSF International against
NSF/ANSI Standard 42 for the
reduction of Chlorine taste
and odor.
Filter system PURITY Quell ST/ Quell GY with fi lter cartridge
PURITY 450 Quell ST
distributor
MDU*
head
300 l/h
350 l/h
60 l/h
60 l/h
0,12 bar
0,08 bar
3,9 l
10 kg/12 kg
2240 l
249 mm/212 mm/408 mm 249 mm/212 mm/520 mm 288 mm/255 mm/550 mm
The PURITY Quell ST fi lter system can be operated either vertically or horizontally.
The PURITY 600 and 1200 Quell GY water fi lter systems must only be operated in
Comparable capacity according to DIN 18879-1:2007
2240 litres
4420 litres
7253 litres
PURITY 600 Quell ST
PURITY 1200 Quell ST
PURITY 600 Quell GY
PURITY 1200 Quell GY
distributor
MDU*
head
2 bar – max. 6,9 bar
4°C – 30°C
10°C – 40°C
–20°C to 50°C
300 l/h
350 l/h
120 l/h
120 l/h
0,36 bar
0,27 bar
5,8 l
12 kg/15 kg
4420l
the vertical position.
G 1"
G 3/4"
distributor
MDU*
head
300 l/h
340 l/h
120 l/h
120 l/h
0,32 bar
0,24 bar
10,9 l
18 kg/24 kg
7253 l