15.1 Building In
558
573
min. 550
20
590
min. 560
min. 550
20
600
min. 560
15.2 Securing the appliance to
the cabinet
1.
Open the appliance door.
2.
Fasten the appliance to the cabinet.
Put the four distance holders (A) into
the holes in the frame and then tight-
en the four screws (B) supplied with
the appliance.
548
20
589
594
5
15.3 Electrical installation
WARNING!
Only a qualified person must do
the electrical installation.
The manufacturer is not responsi-
ble if you do not follow the safety
precautions from the chapter
"Safety Information".
This appliance is supplied with a main
plug and a main cable.
15.4 Cable
Cable types applicable for installation or
replacement: H07 RN-F, H05 RN-F, H05
RRF, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.
For the section of the cable refer to the
total power (on the rating plate) and to the
table:
Section of the ca-
Total power
maximum 1380
3 x 0.75 mm²
W
maximum 2300
3 x 1 mm²
W
maximum 3680
3 x 1.5 mm²
W
The earth cord (green / yellow cable) must
be 2 cm longer than phase and neutral
cables (blue and brown cables).
ENGLISH
31
A
B
ble