Caution: At the last fixture, the DMX cable has to be terminated. Plug the terminator with a 120
between Signal (–) and Signal (+) in the DMX output of the last fixture.
Master/Slave operation
The master/slave operation enables that several devices can be synchronized and controlled by one master
device.
On the rear panel of the device you can find an XLR jack and an XLR plug, which can be used for
connecting several devices.
Choose the device which is to control the effects. This device then works as master device and controls all
other slave devices, which are to be connected to the master device via a DMX-cable. Connect the OUT jack
with the IN plug of the next device.
Set the DMX start address 001 on every slave-device.
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the spot to the mains, the EUROLITE LED ML-56 QCL RGBW/RGBA 18x8W starts
running.
The LED display lights up and you can choose the desired settings.
The device has two operating modes. It can be operated in Stand Alone or in DMX-controlled mode.
- STAND ALONE-MODE
• Setting Solid Colors
• Internal Programs
• Sound Control / Sensitivity
- DMX MODE
International
L
N
23/28
resistor
00060554.DOC, Version 1.1