DMX512 control
The wires must not come into contact with each other, otherwise
the devices will not work at all, or will not work properly.
Please note, the starting address depends upon which controller is being used.
Only use a DMX cable and 3-pin XLR plugs and connectors in order to connect the controller with the fixture
or one fixture with another.
Occupation of the XLR connection:
If you are using controllers with this occupation, you can connect the DMX output of the controller directly
with the DMX input of the first device in the DMX chain. If you wish to connect DMX controllers with other
XLR outputs, you need to use adapter cables.
Building a serial DMX chain:
Connect the DMX output of the first device in the DMX chain with the DMX input of the next device. Always
connect one output with the input of the next device until all devices are connected.
Caution: At the last fixture, the DMX cable has to be terminated. Plug the terminator with a 120
resistor
between Signal (–) and Signal (+) in the DMX output of the last fixture.
The DMX connection can be made via DMX adapters or special DMX connection cables. The important thing
about this is that the connection is always sufficiently isolated against humidity.
Master/Slave operation
The master/slave operation enables that several devices can be synchronized and controlled by one master
device.
On the rear panel of the device you can find an XLR jack and an XLR plug, which can be used for
connecting several devices.
Choose the device which is to control the effects. This device then works as master device and controls all
other slave devices, which are to be connected to the master device via a DMX-cable. Connect the OUT jack
with the IN plug of the next device.
Set the desired master mode for the master-device, as described in chapter Control Board. Set the DMX
address 1 for all slave-devices.
28/39
00095253.DOC, Version 1.0