3.7. Electric heater insulation resistance

When performing the final inspection of the electrical
installations, a "leakage" may be detected when
measuring the heater's insulation resistance. The
reason for this is that the insulating material of the
heating resistors has absorbed moisture from the air
(storage transport). After operating the heater for a
few times, the moisture will be removed from the
resistors.
Do not connect the power feed for the heater
through the RCD (residual current device)!

4. SPARE PARTS

1.
Heating element 1500W/230V
2.
Heating element 2000W/230V
3.
Heating element 2670W/230V
4.
Heating element 3000W/230V
5.
Timer
6.
Thermostat
7.
End-piece of the conn. box
8.
Air flow spoiler
9.
Air flow spoiler
10.
Air flow spoiler
18
10
9
8
6 6
7
DE
3.7. Isolationswiderstand des
Elektrosaunaofens
Bei der Endkontrolle der Elektroinstallationen kann
bei der Messung des Isolationswiderstandes ein
"Leck" auftreten, was darauf zurückzuführen ist,
daß
Feuchtigkeit
Isolationsmaterial der Heizwiderstände eingetreten
ist (bei Lagerung und Transport). Die Feuchtigkeit
entweicht aus den Widerständen nach zwei
Erwärmungen.
Schalten Sie den Netzstrom des Elektrosaunaofens
nicht über den Fehlerstromschalter ein!

4. ERSATZTEILE

5
Heizelement 1500W/230V
Heizelement 2000W/230V
Heizelement 2670W/230V
Heizelement 3000W/230V
Uhrschalter
Thermostat
Stirnstück des Anschlußgehäuses
Luftleitführung
Luftleitführung
Luftleitführung
aus
der
Luft
in
1 2 3 4
ZSK-690
ZSK-700
ZSK-710
ZSK-720
(M90E)
ZST-510
(M)
ZSK-520
(M)
ZST-50
ZST-103
ZST-167
ZST-460
das

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

M45eM80M60M60eM80eM90e

Inhaltsverzeichnis