AFFINITY 700:
These devices have 2 UV low pressure lamps in the facial tanner.
The facial tanner's UV low pressure lamps must be removed first so that the
UV high pressure lamps can be changed.
Remove the lamps.
AFFINITY 900 / 990:
These devices have 3 UV low pressure lamps in the facial tanner.
Remove the lamps.
Remove the two upper low pressure lamps in the canopy so that you can
then access the facial tanner's low pressure lamp starter.
Replacing lamps: see page 56.
Replacing starters: see page 57.
UV high pressure lamps and filter panels: see page 58.
The assembly is the same process in reverse order.
When assembling the device please note:
Support the canopy panel with one hand so that it does not fall down.
Re-lock the locks: first the lock in the middle, then the outer locks.
Cleaning and maintenance
Operating instructions – 61/86