19
Technische Kennwerte
Technische Kennwerte MBASE+ und MTECH+
Funk-
Messgröße
Anzeigebereich
tion
0 ... 99,9 V
U
L-PE
U
100 ... 600 V
N-PE
15,0 ... 99,9 Hz
f
100 ... 999 Hz
0 ... 99,9 V
U
U
3~
100 ... 600 V
0 ... 99,9 V
U
SONDE
100 ... 600 V
0 ... 99,9 V
U
L-N
100 ... 600 V
U
0 ... 70,0 V
IN
10 ... 999
1,00 k ... 6,51 k
3 ... 999
1 k ... 2,17 k
1 ... 651
R
E
0,3 ... 99,9
100 ... 217
0,2 ... 9,9
I
N
10 ... 130
I
(I
= 6 mA)
1,8 ... 7,8 mA
N
F
I
I
(I
= 10 mA)
3,0 ... 13,0 mA
F
N
F
I
(I
= 30 mA)
9,0 ... 39,0 mA
N
F
I
(I
= 100 mA)
30 ... 130 mA
N
F
I
(I
= 300 mA)
90 ... 390 mA
N
F
I
(I
= 500 mA)
150 ... 650 mA
N
F
U
/ U
= 25 V
0 ... 25,0 V
I
L
U
/ U
= 50 V
0 ... 50,0 V
I
L
t
(I
· 1)
0 ... 1000 ms
N
A
t
(I
· 2)
0 ... 1000 ms
N
A
t
(I
· 5)
0 ... 40 ms
N
A
Z
(
)
0 ... 999 m
L-PE
1,00 ... 9,99
Z
L-N
0 ... 999 m
Z
1,00 ... 9,99
L-PE
+ DC
10,0 ... 29,9
0 ... 9,9 A
Z
I
(Z
,
L-PE
K
L-PE
10 ... 999 A
1,00 ... 9,99 kA
Z
+ DC)
Z
L-PE
10,0 ... 50,0 kA
L-N
0,5 ... 9,99
10,0 ... 99,9
Z
(15 mA)
L-PE
100 ... 999
100 ... 999 mA
I
(15 mA)
0,00 ... 9,99 A
K
10,0 ... 99,9 A
0 ... 999 m
R
(mit Sonde)
1,00 ... 9,99
E
10,0 ... 99,9
[R
(ohne Sonde)
100 ... 999
E
Werte wie Z
]
L-PE
R
1 k ...9,99 k
E
0 ... 999 m
1,00 ... 9,99
R
DC+
E
10,0 ... 29,9
U
0 ... 253 V
E
R
0 ... 999
R
E
E
Sel
0 ... 999
R
DC+
Zange
E
EX-
Z
0 ... 30 M
ST
TRA
1 ... 999 k
1,00 ... 9,99 M
10,0 ... 49,9 M
1 ... 999 k
1,00 ... 9,99 M
10,0 ... 99,9 M
1 ... 999 k
R
, R
ISO
E ISO
1,00 ... 9,99 M
R
ISO
10,0 ... 99,9 M
100 ... 200 M
1 ... 999 k
1,00 ... 9,99 M
10,0 ... 99,9 M
100 ... 500 M
10 ... 999 V–
U
1,00 ... 1,19 kV
0,01 ... 9,99
R
R
10,0 ... 199,9
LO
LO
82
Eingangs-
Auf-
impedanz/
Messbereich
lösung
Prüfstrom
0,1 V
0,3 ... 600 V
1 V
0,1 Hz
DC 15,4 ... 420 Hz
1 Hz
0,1 V
5 M
0,3 ... 600 V
1 V
0,1 V
1,0 ... 600 V
1 V
0,1 V
1,0 ... 600 V
1 V
0,1 V
0,3 · I
5 ... 70 V
N
1
I
= 10 mA · 1,05
N
0,01 k
1
I
= 30 mA · 1,05
N
0,01 k
Rechenwert
1
I
=100 mA · 1,05
aus
N
0,1
R
= U
/ I
E
IN
I
=300 mA · 1,05
N
1
0,1
I
=500 mA · 1,05
N
1
1,8 ... 7,8 mA
1,8 ... 7,8 mA
0,1 mA
3,0 ... 13,0 mA
3,0 ... 13,0 mA
9,0 ... 39,0 mA
9,0 ... 39,0 mA
1 mA
30 ... 130 mA
30 ... 130 mA
1 mA
90 ... 390 mA
90 ... 390 mA
1 mA
150 ... 650 mA
150 ... 650 mA
0 ... 25,0 V
0,1 V
wie I
0 ... 50,0 V
1 ms
6 ... 500 mA
0 ... 1000 ms
1 ms
2 · 6 ... 2 · 500 mA
0 ... 1000 ms
1 ms
5 · 6 ... 5 · 300 mA
0 ... 40 ms
0,15 ... 0,49
0,50 ... 0,99
1 m
1,00 ... 9,99
0,01
0,1
0,25 ... 0,99
1,3 ... 3,7 A AC
1,00 ... 9,99
0,5/1,25 A DC
0,1 A
120 (108 ... 132) V
1 A
230 (196 ... 253) V
10 A
400 (340 ... 440) V
100 A
500 (450 ... 550) V
0,01
0,1
10 ... 100
1
100 ... 1000
15 mA AC
1 mA
Rechenwert abh.
0,01 A
von U
und Z
N
0,1 A
I
=U
/10...1000
K
N
0,15 ... 0,49
1,3 ... 3,7 A AC
1 m
0,50 ... 0,99
1,3 ... 3,7 A AC
0,01
1,0 ...9,99
1,3 ... 3,7 A AC
0,1
10 ...99,9
400 mA AC
1
100 ...999
40 mA AC
0,01 k
4 mA AC
1 k ...9,99 k
1 m
0,25 ... 0,99
1,3 ... 3,7 A AC
0,01
1,00 ... 9,99
0,5/1,25 A DC
0,1
1 V
—
Rechenwert
1 m...
1
1,3 ... 2,7 A AC
0,25 ... 300
0,5/1,25 A DC
1 m...
1
10 k ... 199 k
1 k
2,3 mA bei 230 V
200 k ... 30 M
1 k
10 k
100 k
1 k
10 k
100 k
1 k
I
= 1,5 mA
50 k... 500 M
K
10 k
100 k
1 M
1 k
10 k
100 k
1 M
1 V
10 ... 1,19 kV
10 V
200 mA
0,1 ... 5,99
10 m
I
m
6,0 ... 100
100 m
I
< 200 mA
m
Betriebsmess-
Nennwerte
unsicherheit
(2% v.M.+5D)
1)
(2% v.M.+1D)
(0,2% v.M.+1D) (0,1% v.M.+1D)
U
= 120/230/
N
400/500 V
(3% v.M.+5D)
(3% v.M.+1D)
2
f
= 16
/
/50/
N
3
(2% v.M.+5D)
60/200/400 Hz
(2% v.M.+1D)
(3% v.M.+5D)
1)
(3% v.M.+1D)
+10% v.M.+1D
U
=
N
120 V
230 V
2)
400 V
N
f
= 50/60 Hz
N
U
= 25/50 V
L
I
=
N
6 mA
(5% v.M.+1D) (3,5% v.M.+2D)
10 mA
30 mA
100 mA
300 mA
2)
500 mA
+10% v.M.+1D
4 ms
(10% v.M.+30D)
U
= 120/230 V
N
1)
(10% v.M.+30D)
400/500 V
(5% v.M.+3D)
2
8)
f
=16
/
/50/60 Hz
N
3
(18% v.M.+30D)
U
= 120/230 V
N
(10% v.M.+3D)
f
= 50/60 Hz
N
Rechenwert aus Z
nur Anzeigebereich
(10% v.M.+10D)
(8% v.M.+2D)
U
= 120/230 V
N
2
8)
f
= 16
/
/50/
N
3
Rechenwert aus Z
60 Hz
:
L-PE
I
= U
/Z
K
N
L-PE
(10% v.M.+30D)
(10% v.M.+30D)
U
= 120/230 V
(5% v.M.+3D)
N
1)
U
= 400 V
(10% v.M.+3D)
N
f
= 50/60 Hz
(10% v.M.+3D)
N
(10% v.M.+3D)
U
= 120/230 V
±(18% v.M.+30D)
N
(10% v.M.+3D)
f
= 50/60 Hz
N
(20% v.M.+20 D) (15% v.M.+20 D)
siehe R
E
4)
U
= 120/230 V
(22% v.M.+20 D) (15% v.M.+20 D)
N
f
= 50/60 Hz
N
(20% v.M.+2D)
U
= U
(10% v.M.+2D)
0
L-N
U
= 50 V
N
I
= 1 mA
N
U
= 100 V
N
I
= 1 mA
Bereich
k
N
(5% v.M.+10D)
U
= 250 V
N
Bereich
M
I
= 1 mA
(5% v.M.+1D)
N
U
= 500 V
N
U
= 1000 V
N
I
= 1 mA
N
(3% v.M.+1D) ±(1,5% v.M.+1D)
(4% v.M.+2D)
U
= 4,5 V
0
Anschlüsse
Eigen-
Stecker-
2-Pol-
3-Pol-
unsicherheit
einsatz
Adapter
Adapter
1)
(1% v.M.+5D)
(1% v.M.+1D)
l
l
l
(2% v.M.+5D)
l
(2% v.M.+1D)
(1% v.M.+5D)
(1% v.M.+1D)
(2% v.M.+5D)
l
l
(2% v.M.+1D)
+1% v.M.–1D ...
+9% v.M.+1D
l
l
+1% v.M.–1D ...
+9% v.M.+1 D
3 ms
(5% v.M.+30D)
(4% v.M.+30D)
(3% v.M.+3D)
(6% v.M.+50D)
(4% v.M.+3D)
l
l
L-PE
Z
L-PE
(2% v.M.+2D)
(1% v.M.+1D)
(15 mA):
L-PE
(15 mA)
(5% v.M.+30D)
(4% v.M.+30D)
(3% v.M.+3D)
(3% v.M.+3D)
(3% v.M.+3D)
l
l
(3% v.M.+3D)
(6% v.M.+50D)
(4% v.M.+3D)
(10% v.M.+3D)
l
l
l
(5% v.M.+3D)
Bereich
k
(3% v.M.+10D)
l
l
Bereich
M
(3% v.M.+1D)
l
(2% v.M.+2D)
GMC-I Messtechnik GmbH
Zangen
Sonde
WZ12
Z3512
MFLEX
C
A
P300
l
l
wahl-
weise
l
l
l
l