Technical Data

Garden pump set .......FGPS 1100 C3
Mains connection .............230 V~, 50 Hz
Power consumption ................... 1100 W
Suction lift ....................................... 7 m
Max. discharge rate ...............4.600 l/h*
Max. discharge head (Hmax) .......... 45 m
Max. water temperature (Tmax) ...... 35 °C
Hose connection ................. 1" (30.3 mm)
Safety class .......................................... I
Degree of protection .........................IPX4
Sound pressure level
(L
) ................ 69.5 dB(A); K
pA
Sound power level (L
measured ......81.6 dB(A); K
guaranteed ............................ 85 dB (A)
*
With the included suction hoss (
the maximum discharge rate of the garden
pump can not be reached.
Technical and optical changes can be car-
ried out in the course of further development
without notice. All dimensions, references
and information of this instruction manual
are without guarantee. Legal claims, which
are made on the basis of the instruction
manual, cannot thus be considered as valid.
Tighter hoses can reduce the output.
16
=3 dB(A)
pA
)
WA
=2.16 dB(A)
WA
14),

Notes on Safety

This section deals with the general safety
regulations for working with the equip-
ment.

Symbols in the manual

Warning symbols with in-
formation on damage and
injury prevention.
Instruction symbols (the instruction is
explained at the place of the excla-
mation mark) with information on
preventing damage.
Help symbols with information on
improving tool handling.

Symbols on the equipment

Caution! Not suitable for water
with a high sand content!
Read and follow the operating in-
structions provided for the device!
Attention: Remove the plug from the
socket as soon as the power lead is
damaged or cut.
Information of the acoustic power
level L
in dB
WA
G1"
IN
Water inlet
G1"
OUT
Water outlet
Electric appliances should not be
disposed of in the domestic gar-
bage.