Herunterladen Inhalt Inhalt Diese Seite drucken

Defining The Cascade Mode Of The Central Module - Guntermann & Drunck DVICenter DP64 Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Defining the cascade mode of the central module

The central modules detect independently whether they are installed as master or as
slave device within the KVM matrix system.
NOTE:
Changing the cabling of the devices by accident can also change the operat-
ing mode of the central module.
To avoid accidental changes, you can adjust the operating mode of each central
module separately in the on-screen display of the respective device.
How to change the cascade mode of a central module:
1. Press
Ctrl
(default) to open the on-screen display.
2. Press
F11
to call the Configuration menu.
3. Select the
entry and press
System
4. Select the
Cascade mode
Auto:
The central module defines if it works in the master or slave mode.
Master:
In this operating mode, you can only connect user modules to
Dynamic Ports that are configured for the connection of target mod-
ules.
You can change the names of the connected target modules. The
changed names are automatically updated on the slave devices of the
cascade.
Slave:
In this operating mode, you cannot change the names of connected
target modules. The names of the target modules are automatically
obtained from the master device.
5. Press
F2
to save your settings.
Central Module » Expanding the KVM matrix system by cascading
.
Enter
entry and press
F8
to choose one of the listed options:
G&D DVICenter DP64 · 20

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis