Warning messages
If a warning is present, a running combustion process will be stopped. As long as the appliance is in the combustion
process the warning message will be continuously visible.
If an error message occurs in idle status, start of the combustion process will not be allowed. The warning message
is visible every 30 seconds for 5 seconds.
Display
automatic
door open
ESC
automatic
ext. request
blocked
ESC
automatic
outside
time program
ESC
automatic
flame temp.
too hot
ESC
automatic
room temp.
too hot
ESC
automatic
cover open
ESC
60
Possible cause of error
Combustion chamber door open.
The temperature set on the external
room thermostat is lower than the actu-
al room temperature.
Active time programs are stored, howev-
er the actual time is outside of the current
time programs.
In addition, in "automatic" mode no night
set temperature is stored.
The flame temperature is too high.
The actual room temperature is too high
(only for "automatic" mode).
Pellet tank cover open.
Elimination
Close combustion chamber door.
Wait until the actual room temperature
has cooled and the appliance starts au-
tomatically.
Increase the desired temperature on the
room thermostat.
Wait until the actual time is within the ac-
tive time programs and the appliance
starts automatically.
Redefine time programs.
Define night set.
Wait until the flame temperature has
cooled and the appliance starts automat-
ically.
Wait until the actual room temperature
has cooled and the appliance starts au-
tomatically.
Increase the desired room temperature.
Close pellet tank cover.