Settings "language"
Display
language
Deutsch
English
Français
Settings "convection"
only for pellet stove with rated heat output 6 kW
Display
settings
date & time
language
convect.
n.c.
settings
date & time
language
convect.
off
Settings "frost protection"
Display
settings
language
convect.
auto
frost pro
---
52
Action
Description
The following languages can be selected:
or
Deutsch, English, Français
Select the language with ↓ or ↑ and confirm with
(ENTER).
Action
Description
The convection air blower is an accessory.
If a connection air blower has not been installed
"n.c." (not connected) will be displayed.
If a convection air blower is installed the following
can be set:
- off:
The convection air blower is switched off.
- blower speed: level 1-5
- automatic mode "auto":
or
In this case the appliance selects a suitable blow-
er speed based on the heat power.
Factory setting: off
Select "off with (ENTER) ("off" flashes), with ↓ or ↑
set the value and confirm with (ENTER).
Action
Description
The frost protection function is active when the ac-
tual room temperature drops below the set frost pro-
tection temperature. The combustion process starts
automatically for at least 30 minutes. This happens
also in the operating status "off" (main switch must
be turned on). As soon as the actual room tempera-
ture increases above the set frost protection temper-
ature, the combustion process will be ended again
and the system will revert to the previously selected
or
operation mode.
The frost protection temperature can be set at 5°C to
10°C or to no frost protection temperature (---).
Factory setting: ---
Select the temperature with (ENTER) ("---" flashes),