Installation sequence
● Determine the installation location. Objects made
of flammable materials must not be present in, or
be placed in the radiation area of the wood-burn-
ing stove to a distance of 80 cm, measured from the
view pane of the combustion chamber door.
Depending on the installation position of the stove in
front of walls that need to be protected (flammable
or load-bearing), the following distances from walls
need to be observed in accordance with the position
of the combustion chamber door to the wall / side
panel or the back panel (see schematic diagram).
When not dealing with walls that need to be protect-
ed, you merely need to observe a minimum distance
of approx. 5 cm to allow for proper heat
10
Dimensions in cm
● Install the pipe lining (customer-provided) in the
chimney. The connection height can be individual-
ly determined, however it should not exceed 1.5 m
from the connection duct. There should be no flam-
mable material within a 20 cm radius around the
waste gas pipe, for the passage through structural
components made of flammable materials.
● If desired, remount combustion air duct for the con-
nection from below (see chapter, "Modification of
combustion air duct for connection from below").
● Fit the waste gas pipe (customer provided) on the
connection duct Ø 80 mm of the appliance.
● Fit the combustion air line Ø 80 mm on the combus-
tion air duct.
● Slide and align the stove at the intended installation
location in such a manner that the waste gas pipe fits
into the pipe lining.
The waste gas pipe connections must be sealed.
In order to clean the connecting line, bends with a
cleaning opening must be used.
The waste gas pipe must not project into the chim-
ney.
Bear in mind that on partition walls in accordance
with test specification EN 13240, the temperature
of 85°C can be reached, and with light wallpaper
or similar combustible construction materials this
can result in colour changes.
Modification of the combustion air duct
for connection from below
● Dismount the lower rear wall and panel (Fig.2)
● Unscrew the combustion air duct (Fig.3).
● Screw the combustion air duct onto the floor plate
(Fig.4).
● Remount the panel and lower rear wall.
● Seal the hole in the lower rear wall for the combus-
tion air connection at the back with the included cov-
er and screws.
dissipation..
Fig.2
Fig.3
Fig. 4
Panel
Screws combustion air duct
Lower rear wall
39