BACKWASH INSTRUCTIONS
When you first start up your filter, we recommend that you let it run
for two weeks before you perform your first backwash. After that, 2 -
3 times a week during the warm season should be all that is needed.
During the winter months backwashing can be reduced to as little as
once every 2-3 weeks. To perform a backwash do the following:
1.
With the pump running open the valve to the sludge drain (B).
Keep it open for 15-20 seconds, then shut it. This will purge the
large solids that have made it into the filter and settled out in the
bottom of the tank to waste. It is very important to get them out
of the system for overall water quality and more efficient filter
operation.
2.
Next turn off the pump.
3.
Move the multiport valve to the rinse position. When the blower
(D) is activated in this position, air and a small amount of water
with leave the filter to waste. It is important that the valve be in
the rinse position for the blower agitation of the beads.
4.
Activate the blower unit for 1-2 minutes. During this time the beads and debris are dispersed throughout the interior of
the filter. This breaks up the beads and releases the trapped particles. This debris then can easily be backwashed out
to waste. Place your ear to the side of the tank. You should hear a lot of "plopping and sloshing" going on inside the
filter. If you only hear air moving through the filter then you need to open the tank and make sure that the beads are
not gelled.
5.
!!IMPORTANT!! Some water has been forced out of the filter. The tank needs to be entirely full of water before
backwash is performed. To fill the tank with water, open the air release valve at the top of the filter and turn on the
pump. When water sprays out the air release valve, the tank is full. Turn off the pump and shut the air release valve.
6.
Move the valve to the backwash position. Turn on the pump and run until the water is clear in the sight glass. The
water will run clear at first then dark and then clear.
7.
Move the multiport valve to the rinse position. Turn on the pump and run until water is clear in the sight glass. This
takes any remaining debris and sends it to waste, instead of sending a cloud of dirt back to the pond. Turn off the
pump.
8.
Move the multiport valve to the filter position and turn on the pump. Backwash is done.
*Note* The backwash instructions on the label of the blower are a short version of the above instructions.
WATER SAVING DRAIN: The EconoBead filters EB40/50/60 come standard with a water saving sludgedrain.
The water saving sludgedrain allows a low volume backwash if water is in short supply, expensive, or you have
a low volume pond, but heavily stocked. After using the Blower or an initial hydraulic backwash to break up the
bead pack, let the heavy solids settle in the water below the bead pack then open the Sludgedrain and drain
them to waste. The sludge drain will allow the entire tank to be drained, without losing beads through the sludge
drain. So one is only using the water volume of the filter tank to wash the beads. This saves many gallons of
water that may be used with an hydraulic backwash. This is only valid for the EB40/50/60, not for the
EB100/140! The EB100/140 do not have a valve outlet with strainer which causes the beads to come out of the
filter. Keep close attention when the beads start coming out of the filter and close it.
NOTE: The "normal" backwash procedure does cost more water, but by refilling your pond after backwash you
will make, necessary, water changes automatically! Water changes of 5 to 10% per week are a good rule of
thumb for most ponds.
7
E
D
C
A
B

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Aqua Forte EconoBead EB-40

Inhaltsverzeichnis