Commissioning
Code table
Code
Possible settings
No.
Name
Lenze
C0007
Fixed configuration of
digital inputs
uSEr
C0007
uSEr
(cont.)
C0007
uSEr
(cont.)
C0007
uSEr
(cont.)
104
Selection
0
E4
0
CW/CCW
1
CW/CCW
2
CW/CCW
3
CW/CCW
4
CW/CCW
5
CW/CCW
6
CW/CCW
7
CW/CCW
8
CW/CCW
9
CW/CCW
10
CW/CCW
TRIP set
E4
11
CW/CCW
12
CW/CCW
13
CW/CCW
14
CCW/QSP
CW/QSP
15
CCW/QSP
CW/QSP
16
CCW/QSP
CW/QSP
17
CCW/QSP
CW/QSP
18
CCW/QSP
CW/QSP
19
CCW/QSP
CW/QSP
E4
20
CCW/QSP
CW/QSP
21
CCW/QSP
CW/QSP
22
CCW/QSP
CW/QSP
23
H/Re
CW/CCW
24
H/Re
25
H/Re
26
H/Re
JOG1/3
27
H/Re
TRIP set
28
JOG2/3
JOG1/3
29
JOG2/3
30
JOG2/3
E4
31
DCB
32
TRIP set
33
QSP
34
CW/QSP
CCW/QSP
35
JOG2/3
JOG1/3
36
DCB
37
JOG1/3
38
JOG1/3
39
JOG2/3
JOG1/3
40
JOG1/3
EDK82EV903 DE/EN/FR 2.1
E3
E2
E1
DCB
JOG2/3
JOG1/3
PAR
JOG2/3
JOG1/3
QSP
JOG2/3
JOG1/3
PAR
DCB
JOG1/3
QSP
PAR
JOG1/3
DCB
TRIP set
JOG1/3
PAR
TRIP set
JOG1/3
PAR
DCB
TRIP set
QSP
PAR
TRIP set
QSP
TRIP set
JOG1/3
UP
DOWN
E3
E2
E1
DCB
UP
DOWN
PAR
UP
DOWN
QSP
UP
DOWN
DCB
JOG1/3
PAR
JOG1/3
JOG2/3
JOG1/3
PAR
DCB
PAR
TRIP set
DCB
TRIP set
E3
E2
E1
TRIP set
JOG1/3
UP
DOWN
UP
JOG1/3
UP
DOWN
PAR
UP
DOWN
DCB
UP
DOWN
UP
DOWN
UP
DOWN
DFIN1-ON
PCTRL1-I-OFF
DCB
DFIN1-ON
PCTRL1-I-OFF
QSP
DFIN1-ON
PCTRL1-I-OFF
E3
E2
E1
QSP
DFIN1-ON
PCTRL1-I-OFF
QSP
DFIN1-ON
PCTRL1-I-OFF
PAR
DFIN1-ON
PCTRL1-I-OFF
DFIN1-ON
PCTRL1-I-OFF
PAR
DFIN1-ON
QSP
PAR
DFIN1-ON
QSP
PAR
DFIN1-ON
PAR
TRIP set
DFIN1-ON
TRIP set
DFIN1-ON
QSP
TRIP set
DFIN1-ON
IMPORTANT
Change under C0007 will be copied to the
corresponding subcode of C0410. Free
configuration under C0410 sets C0007 =
255!
CW/CCW = CW rotation/CCW rotation
DCB = DC injection brake
QSP = Quick stop
PAR = Parameter set changeover (PAR1
PAR2)
– PAR1 = LOW, PAR2 = HIGH
– The terminal must be assigned to the
function "PAR" in PAR1 and PAR2.
– Configurations with "PAR" are only
allowed if C0988 = 0
TRIP set = external fault
JOG1/3, JOG2/3 = Selection of fixed
setpoints
– Activate JOG1:
JOG1/3 = HIGH; JOG2/3 = LOW
– Activate JOG2:
JOG1/3 = LOW; JOG2/3 = HIGH
– Activate JOG3:
JOG1/3 = HIGH; JOG2/3 = HIGH
UP/DOWN = motor potentiometer functions
H/Re = Hand/remote changeover
PCTRL1-I-OFF = Switch off process
controller I component
DFIN1-ON = Digital frequency input 0 ... 10
kHz
PCTRL1-OFF = Switch off process controller