Dimensions
technical
data
SC Serie
Footprint height
SC 1455
255x150
* it is best to chose the max. water level
malfunction
Pump produces
insufficient air
excessive air bubbles in
aquarium water
Pump does not start
Disassembly of the pump: see page 27
The Deltec skimmer range should need very little adjustment and maintenance once set
correctly however due to the high levels of calcium in marine aquariums it is common for
deposits to build up on moving parts requiring periodical cleaning . Deltec pump is fitted
with a little flap inside the outlet of the pump, which flip from one side to the other
depending on the direction of rotation thus ensuring that the pump always operates at full
duty. It is recommended every 6 months, or when required, that the pumps are removed
from the skimmer having first drained the body of Water.
Check and clean the impellor of debris. Ensure that the direction flap move easily and if
necessary soak the neck of the pump housing in white vinegar or lime scale remover to
dissolve any calcium carbonate deposits. A build up of calcium, dust and salt can restrict or
block the venturi inlet on the connecting pipe work and reduce the skimming efficiency. This
should be checked and carefully cleaned with a toothpick or fine drill rotated between the
fingertips.
It is advisable to stop the pump for approximately 15 minutes once every week in order to
dissolve any dust or salt crystals that may have collected in the venture tube.
Please observe: The water level adjuster must be checked at regular intervals (at least
once a week) for accumulation of dirt or other substances with may inhibit or interfere with
its proper function. If required please clean. For this purpose the water level adjuster can be
simply removed by pulling it upwards. After reinstallation of the water level adjuster please
make sure it is correctly set. Any foreign bodies, limestone build up ect. can cause the
skimmer water level to raise, in extreme cases the skimmer may get flooded.
Technical data
Aquarium size
mm
litre
high
normal
stocking
stocking
550
800
1000
Fault finding
cause
airline or venturi blocked
airline kinked
ozonizer blocked
Pump flaps blocked
caused by additives in certain sea
salts and water conditioners
Bearing of the impeller stuck. When
the pump (after having been used) has
been stored dry for a period of time,
the bearing can "dry out".
Impeller incorrectly fitted
Maintenance
Water level
Power
required hight*
consumption
mm
Watt
min.
max.
min.
140
240
11
remedy
clean
remove kink
clean
clean
Use different salt or feed heavily
for a period, empty skimmer cup
frequently. This condition may
last for several weeks.
Remove impeller with as illustrated and
loosen the bearing by moving the
bearing plate around and along the
ceramic shaft in tap water.
See service hints
-12-
Air
Connections
litre/h
max.
min.
max.
600
Ø mm
Outlet
32