Herunterladen Inhalt Inhalt Diese Seite drucken

Kurtz Ersa DIGITAL 2000 A Bedienungsanleitung Seite 56

Vorschau ausblenden Andere Handbücher für DIGITAL 2000 A:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Functional description
5.6
Factory Pre-Settings
The following is a list of the factory pre-settings for the individual programs.
Table 8: Factory pre-settings
Program
Setpoint
Unit
Standby (min)
Tip Offset
Calibration
Energy
Tool
Other settings:
Program Pr1
Password = 0 (disabled)
The station can be reset to the above factory settings. To this end, first switch off the sta-
tion. Now press the ENTER key. While keeping this key pressed, keep the station switched
on until the display test is concluded (all segments light up briefly)
5.7
Resetting the Password
In the event that a password is forgotten, it can be deleted as described in section 5.5. All
parameters set by the user are then also lost.
ersa DIGITAL 2000 A
Then fasten knurled nut 2. This counters knurled head screw 1 and thus
prevents self-adjustment of the force-limitation device. The opening
angle of the CHIP TOOL may be adjusted using knurled head screw 3. This
function is extremely useful for working with densely-populated printed
circuit boards.
Note:
When not using the CHIP TOOL for a long period of time, please open the
angle to its widest position using the knurled head screw 3. Failure to do
so will result in a slight weakening of the spring mechanism.
Pr1
285
°C
0
1
0
1
MICRO TOOL
3BA00044-00 • 2013-06-25 • Rev. 4
Pr2
Pr3
325
360
°C
°C
0
0
1
1
0
0
3
3
TECH TOOL
POWER TOOL
Pr4
385
°C
0
1
0
1
CHIP TOOL
57

Werbung

Inhaltsverzeichnis
loading