ROTAX 125 MAX evo, Junior MAX evo, Mini MAX evo, Micro MAX evo
Fix another cable tie (pos. 1) at the fixing point (bore) on the engine housing. Secure
both lines with cable tie (pos. 3), ensuring that the black hose (pos. 2) must be
overhead.

10. Verification or replenishing of oil level in gear compartment

The gear compartment will have already been filled with the appropriate amount of oil by the
engine manufacturer. However before engine installation in frame, the oil level must be verified or
replenished. See Fig. 41.
Place engine on a horizontal surface and/or and/or assembling trestle.
 Note:
To measure the oil level exactly, drain the gear oil and determine it using a
measuring cup.
Loosen Allen screw (pos. 1) with gasket ring (pos. 2) and absorb the leaking oil in a
measuring cup. If necessary, remove the air vent screw (pos. 3) to ensure a better
oil drain.
Determine the gear oil using the measuring cup.
 Note:
Oil capacity by new filling is 100 cc (0.026 gal).
 Note:
Specification of gear oil is: Engine oil SAE 15W-40.
Tighten the Allen screw (pos. 1) with new gasket ring (pos. 2). Tightening torque
10 Nm.
Replenish new gear oil in the air vent hole.
Hand tightens the air vent screw (pos. 3).
Page 23/53
Fig. 40
Fig. 41
Edition 07/2016