8.3.3 Set analog output min level (sNvm)
This command sets the minimum analog output current level (0 or 4 mA).
Command input:
Return data:
Successful:
Error:
8.3.4 Set analog output value in error case (sNve)
This command sets the analog output current level in mA in case of an error. This level can be lower
as the min level set in 8.3.3 Set analog output min level (sNvm).
Command input:
Return data:
Successful:
Error:
8.3.5 Set distance range (sNv)
Sets the minimum and maximum distances corresponding to the minimum and maximum analog
output current levels.
DIST D
Aout
D
Aout
DIST
D
D
Command input:
Return data:
Successful:
Error:
Printed in the Federal Republic of Germany
11/24/2005
sNvm+x<trm>
N:
Module number (0..9)
x:
Minimum output for analog out
0: Minimum signal is 0 mA
1: Minimum signal is 4 mA
gNvm?<trm>
gN@Ezzz
zzz:
Error code
sNve+xxx<trm>
N:
Module number (0..9)
xxx:
Value in case of an error in 0.1mA
gNve?<trm>
gN@Ezzz
zzz:
Error code
0...20mA
min
20 mA
D
max
min
Analog current output
Actual measured distance
Distance programmed for the minimum output current
min
Distance programmed for the maximum output current
max
sNv+xxxxxxxx+yyyyyyyy<trm>
N:
Module number (0..9)
xxxxxxxx:
Minimum distance in 1/10 mm corresponding to 0mA / 4mA
yyyyyyyy:
Maximum distance in 1/10 mm corresponding to 20mA
gNv?<trm>
gN@Ezzz
zzz:
Error code
TR - ELE - BA - DGB - 0014 - 01
4...20mA
DIST D
min
Aout
D
D
max
min
TR-Electronic GmbH 2005, All Rights Reserved
Command set
16 mA 4 mA
Page 65 of 80