Herunterladen Inhalt Inhalt Diese Seite drucken

Set Digital Output Levels (Snn) - TR-Electronic LLB-30-D Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Command set

8.3.6 Set digital output levels (sNn)

Sets the distance levels at which the digital outputs are switched ON and OFF with a hysteresis.
Two different situations are possible:
ON level > OFF level
The ON level of the hysteresis is larger than the OFF level. With an increasing distance, the digital
DO
closed
open
0
Off
The ON level of the hysteresis is smaller than the OFF level. With a decreasing distance, the digital
DO
closed
open
0
On
Command input:
OFF
Return data:
Successful:
Error:
 TR-Electronic GmbH 2005, All Rights Reserved
Page 66 of 80
output is switched on (open drain output is closed) when
the distance exceeds the ON level. With a decreasing
distance, the digital output is switched off (open drain
output is open) when the distance falls below the OFF
level.
Distance
On
ON level < OFF level
output is switched on (open drain output is closed) when
the distance falls below the ON level. With an increasing
distance, the digital output is switched off (open drain
output is open) when the distance exceeds the OFF
level.
Distance
Off
sNn+xxxxxxxx+yyyyyyyy<trm>
N:
Module number (0..9)
n:
Digital output port (1 or 2)
xxxxxxxx:
Distance ON level in 1/10 mm for switching digital output ON
yyyyyyyy:
Distance OFF level in 1/10 mm for switching digital output
gNn?<trm>
gN@Ezzz
zzz:
Error code
TR - ELE - BA - DGB - 0014 - 01
Printed in the Federal Republic of Germany
11/24/2005