Herunterladen Inhalt Inhalt Diese Seite drucken

Dmx-Controlled Operation; Addressing; Choosing The Functions And Parameters; Dmx-Protocol - EuroLite 51930451 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The pin occupation of the connection-cables is as follows:
Pin:
Occupation:
1
+24V
2
Red
3
Green
4
Green
5
Blue
6
GND

DMX-controlled operation

You can control the devices individually via your DMX-controller.

Addressing

The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from
which the CB-12 DMX Controller will respond to the controller.
For address setting, press the MENU-button until the display shows "A001" and set the desired address via
the Up/Down-buttons.
Controlling:
After having addressed the CB-12 DMX Controller, you may now start operating the LED Balls via your
lighting controller.
Note:
After switching on, the CB-12 DMX Controller will automatically detect whether DMX 512 data is received or
not. If the data is received, the control LED flashes. If there is no data received at the DMX-input, the control
LED lights up permanently.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of CB-12 DMX
Controller.
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap
in the input connector.

Choosing the Functions and Parameters

Press the MENU-button and choose the desired mode.
The desired parameter values can be selected via the UP or DOWN buttons.
MODE
COLOUR
CHS
SPD
CHA
CE
SOU

DMX-Protocol

DMX control possible in 5 channel or 48 channel mode.
VALUE
0~7
0~15
1~16
0~511
5/48
ON/OFF
DESCRIPTION
Color Selection
Internal Chasers
Speed
DMX Addressing
DMX Control Channel Selection
Sound Control
17/20
00080351.DOC, Version 1.3

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

51930450Cb-12/50Cb-12/30

Inhaltsverzeichnis