Connection to the water supply
A shut-off valve with a ¾" connecting thread is required for the connection
to the water supply.
∙ Connect the stainless steel tube to the shut-off valve with the straight
side. Make sure it is screwed in firmly.
∙ Fasten the stainless steel tube to the magnet valve on the lower side of
the device. Make sure it is screwed in firmly and sealed properly.
∙ Open the shut-off valve of the water supply carefully and check the enti-
re water system for leaks.
∙ Now connect the device to the electric power supply.
∙ Slide the device to the desired position. Make sure that the stainless
steel tube is not bent or damaged.
02
Inserting the fragrance: Open the fragrance compartment 6. Twist
open the fragrance cap and insert it into the fragrance holder 7. Insert
up to three fragrances into the fragrance holder 7. Close the fragrance
compartment 6.
The display 1 can be adjusted to three positions.
03
The power cable can be adjusted to the desired length by winding it up in
04
the cable compartment 9.
Attention! The coupling of the mains cable must be plugged firmly into the
device!
Please remove the protective foil for battery and
remote control.
Connect the power plug and
switch on the appliance at the
on/off switch 2 or with the remote control 11.
ATTENTION! Because of the filling process it may may take about 6 minutes for
the device to start.
Description of UVC lamp
The air washer features a built-in UVC lamp 8. The UVC lamp is designed for a
hygienically flawless operation of the air washer and prevents the formation of
germs and bacteria in the water. It is active for 4 hours a day.
ON/OFF
Set fan stage
Venta LW62 WiFi
GB