INSTALLATION
Specification
Controller-limiter combination immersion depths
1
735
1 Limiter sensor
2 Controller sensor
Solar collector sensor immersion depth
16.2 Wiring diagram
1/N/PE ~ 230 V
R1
T2 ϑ
T1
ϑ
N L1
E1
Solar control unit
F1
Sensor solar collector
F2
Sensor DHW
M1
Circulation pump
R1
Heating element, 2 kW ~ 230 V
T1
High limit safety cut-out
T2
Temperature controller
www.stiebel-eltron.com
2
845
300
ϑ ϑ
M1
F1
F2
E1
16.3 Fault conditions
In the event of a fault, temperatures of up to 95 °C at 0.6 MPa
can occur.
16.4 Details on energy consumption
The product data complies with EU regulations relating to the
Directive on the ecological design of energy related products (ErP).
Manufacturer
Energy efficiency class
Cylinder capacity
Standby losses
16.5 Data table
Hydraulic data
Nominal capacity
Capacity, lower indirect coil
Surface area, lower indirect coil
Pressure drop at 1.0 m³/h, lower indirect coil
Mixed water volume at 40 °C (15 °C/60 °C)
Application limits
Max. permissible pressure
Test pressure
Max. permissible temperature
Max. flow rate
Max. recommended collector aperture area
Temperature setting range
Energy data
Standby energy consumption/24 h at 65 °C
Energy efficiency class
Versions
IP rating
Electrical data
Connected load
Rated voltage
Phases
Frequency
Dimensions
Width
Height
Depth
Weights
Weight, full
Weight, empty
KS 150 SOL
074098
STIEBEL ELTRON
B
l
146
W
50.0
KS 150 SOL
074098
l
150
l
7.4
m²
1.2
hPa
18
l
260
MPa
0.6
MPa
0.9
°C
95
l/min
18
m²
2.4
°C
35-82 °C
kWh
1.2
B
IP24
kW
2.0
V
230
1/N/PE
Hz
50
mm
510
mm
1280
mm
510
kg
228
kg
82